Ducts carry the air your furnace, air conditioner or heat pump conditions to each room, so an efficient system can still underdeliver if its ducts leak or choke the airflow. The DOE puts air loss through ducts at about 30% of a cooling system's energy use.[3]
ENERGY STAR says that in a typical house about 20 to 30 percent[1] of the air moving through the duct system is lost to leaks, holes and poorly connected ducts. Its fix is to seal leaks with mastic sealant or metal tape, never duct tape, and insulate the ducts you can reach in attics, crawlspaces, unfinished basements and garages.[1] Each run should be sized to the airflow its room needs; the 2021 International Residential Code points duct design to ACCA Manual D.[15]
How a duct system works
The blower pushes conditioned air through supply ducts to registers in each room, and return ducts bring room air back to the equipment through the filter. The DOE's Building America guide says return air must have a clear path back to the air handler from every room with a supply outlet, except bathrooms and kitchens, and that poor return paths cause pressure imbalances, drafts and temperature differences and make the equipment work harder than necessary.[5] A DOE study found that closing the door of a room raises the resistance on that room's return path.[20]
Duct materials
The EPA notes that many modern residential duct systems are fiber glass duct board or sheet metal lined inside with fiber glass duct liner, and that flexible duct, generally lined inside with plastic or a similar material, has come into much wider use since the early 1970s.[4] Insulated duct material spread because of better temperature control, energy conservation and less condensation, and internal insulation also gives better noise control.[4]
- Sheet metal: rigid round or rectangular duct, sealed at its joints with UL 181 rated mastic or tape.[9]
- Flexible duct: lined inside and sensitive to installation. Compressing it or using excessive length noticeably increases friction losses, the DOE says,[11] and LBNL found that moderate compression typical of field installations could raise pressure drop by a factor of four.[12] See flexible vs. rigid ductwork.
- Duct board: fiber glass panels formed into ducts.[4]
Layouts
- Trunk and branch: a main trunk duct with smaller branch ducts to each room.
- Radial: separate runs from a central plenum or distribution box to each room.
Whichever layout carries the supply air, each room still needs a way for that air to get back to the equipment; see return airflow below.
Sizing
The 2021 International Residential Code requires duct systems to be designed to ACCA Manual D, the manufacturer's instructions or other approved methods.[15] Each duct is sized from the airflow it carries and the friction rate the blower can afford, with room airflow coming from a room-by-room load calculation; the DOE tells homeowners to insist on documented ACCA Manual J calculations.[21] Our ductwork sizing calculator sizes round and rectangular ducts from airflow and friction rate.
A worked example
Picture a bedroom with an example cooling load of 6,000 Btu per hour, which is 6,000 ÷ 12,000 = 0.5 ton, since a ton of cooling is 12,000 Btu per hour.[18] ACCA calls 400 CFM per ton the typical design airflow, with about 350 in hot, humid climates and 450 in drier ones,[17] so at 400 CFM per ton the room needs 0.5 × 400 = 200 CFM.
The calculator sizes 200 CFM at its default friction rate of 0.08 inches of water per 100 feet to a 7.83-inch diameter, which rounds up to an 8-inch round duct. Air in that duct moves at 200 ÷ (π × (8 ÷ 12)² ÷ 4) = 573 feet per minute, and its friction comes to 0.072 inches per 100 feet, under the target. The friction model, Darcy-Weisbach with the Swamee-Jain friction factor for galvanized steel, is a calculator assumption; a Manual D design accounts for fittings and the blower's available pressure.
Return airflow
BASC says a typical door undercut of 1/2 to 3/4 inch[5] isn't an adequate return path and isn't approved in ACCA Manual D.[5] An undercut alone meets ENERGY STAR's room pressure limits only for rooms with under 20 cfm of supply,[8] and a working undercut usually has to be 1.5 inches or more.[8]
Better return paths are a return duct in the room,[5] a transfer grille through the wall or above the door,[6] or a jump duct, a short insulated duct through the attic between ceiling grilles.[7] See cold air return vents.
Leaks and sealing
ENERGY STAR says leaky ducts can reduce heating and cooling efficiency by as much as 20%,[2] and the DOE puts air loss through ducts at about 30% of a cooling system's energy use.[3] Leaky ducts can also pull fumes, insulation particles and dust into the house, and sealing them can help prevent backdrafting of combustion gases.[2]
Seal joints, seams and boots with mastic or UL 181 rated tape, never cloth duct tape: BASC says cloth-backed duct tape can dry out and fail quickly,[9] and in LBNL's accelerated aging tests only one duct tape product survived three months while eleven failed within days.[13] ENERGY STAR adds that the connections at vents and registers, where they meet floors, walls and ceilings, are common places to find leaks and disconnected ducts.[1]
For ducts you can't reach, BASC describes contractors sealing from the inside with a duct blaster and aerosolized acrylic sealant.[10] A duct leakage test pressurizes the ducts to 25 pascals[14] and measures the leakage before and after sealing.
Insulation
The 2021 IECC requires supply and return ducts outside conditioned space to be insulated to at least R-8 for ducts 3 inches in diameter and larger[16] and R-6 for smaller ones.[16] BASC calls R-8 the modern minimum.[10] ENERGY STAR's order of work is to seal the leaks and insulate the ducts you can reach, such as those in attics, crawlspaces, unfinished basements and garages.[1]
Cleaning
The EPA says duct cleaning has never been shown to actually prevent health problems.[4] It suggests considering it when there is substantial visible mold growth inside hard-surface ducts or other parts of the system, when ducts are infested with vermin, or when they are clogged with so much dust and debris that particles come out of the supply registers.[4] Wet or moldy insulated duct can't be effectively cleaned and should be removed and replaced.[4]
See is air duct cleaning worth it for the full EPA guidance.
Repair, seal or replace
Match the fix to what you actually find:
| What you find | What the sources say |
|---|---|
Leaking joints, seams or boots on intact duct | Seal with mastic or metal tape, never duct tape |
Tangled or kinked flexible duct | A sign of poorly performing ducts |
Compressed or overlong flex runs | Friction rises; Manual D sets flex duct design |
Wet or moldy insulated duct | Remove and replace it; it can't be effectively cleaned |
A noisy system | Can mean an undersized duct system or a problem with the indoor coil |
Rooms that are hard to heat and cool | A sign of poorly performing ducts |
When you replace equipment, look at the ducts too: ENERGY STAR says sealing ducts may let you install smaller, less costly heating and cooling equipment.[2]
Frequently asked questions
How much air do leaky ducts lose?
ENERGY STAR says about 20 to 30 percent[1] of the air moving through the duct system in a typical house, through leaks, holes and poorly connected ducts.
How do I know if my ducts are the wrong size?
ENERGY STAR lists rooms that are hard to heat and cool and stuffy rooms among the signs of poorly performing ducts,[1] and says a noisy system can mean an undersized duct system.[19] A Manual D design, which the 2021 International Residential Code points to,[15] or our ductwork sizing calculator shows what each run needs.
Should I have my air ducts cleaned?
The EPA suggests it for substantial visible mold growth, vermin, or ducts so clogged that particles come out of the registers, and says duct cleaning has never been shown to actually prevent health problems.[4]
What's the best way to seal ductwork?
Mastic or UL 181 rated tape over joints and seams;[9] ENERGY STAR says never to use duct tape, as it is not long-lasting.[1] BASC adds mesh tape under the mastic over seams wider than 1/8 inch.[9]
Can I add a return air duct to a room?
Yes. BASC says every room with a supply outlet, except bathrooms and kitchens, needs a clear return path,[5] which a return duct, a transfer grille or a jump duct can provide.[6][7]
A door undercut alone works only for rooms with a small supply flow.[8] See cold air return vents.
Is flexible or metal duct better?
Each works when installed well. Flexible duct's friction rises when it is compressed or overlong,[11] and LBNL found that moderate compression typical of field installations could raise pressure drop by a factor of four,[12] so it has to be designed to Manual D and installed without compression or excess length.[11] See flexible vs. rigid ductwork.
How long does ductwork last?
Judge ducts by condition rather than age. Replace runs that are crushed, disconnected or torn, and insulated duct that has gotten wet or moldy, which the EPA says can't be effectively cleaned.[4] ENERGY STAR's signs of poorly performing ducts, from high bills to tangled or kinked flex duct, make a good checklist.[1]
Sources & References
- ENERGY STAR: Duct Sealing (about 20 to 30 percent of the air lost in a typical house; signs of poorly performing ducts; mastic sealant or metal tape, never duct tape; insulate accessible ducts; vents and registers common leak spots)
- ENERGY STAR: Benefits of Duct Sealing (efficiency reduced by as much as 20%; fumes, insulation particles and dust; backdrafting; may allow smaller equipment)
- U.S. DOE: Energy Saver 101, Home Cooling (PDF): air loss through ducts about 30 percent of a cooling system's energy consumption
- EPA: Should You Have the Air Ducts in Your Home Cleaned? (updated February 19, 2026): duct materials; when to consider cleaning; never shown to prevent health problems; wet or moldy insulated duct replaced
- U.S. DOE Building America Solution Center: Ducted Returns (a return path from every room with a supply outlet except bathrooms and kitchens; 1/2 to 3/4 inch undercuts inadequate, not approved in Manual D)
- U.S. DOE Building America Solution Center: Transfer Grilles
- U.S. DOE Building America Solution Center: Jump Ducts
- U.S. DOE Building America Solution Center: Undercut Doors (ENERGY STAR limits met by an undercut alone only below 20 cfm of supply; usually 1.5 inches or more)
- U.S. DOE Building America Solution Center: Sealed and Insulated Metal Ducts (UL-181, UL-181A or 181B products; cloth-backed duct tape can dry out and fail; mesh tape over seams wider than 1/8 inch)
- U.S. DOE Building America Solution Center: Air Seal and Repair Ducts, DIY guide (aerosol sealing by a contractor; R-8 the modern minimum)
- U.S. DOE Building America Solution Center: No Excessive Coiled or Looped Flex Ducts (compression or excessive length increases friction losses; Manual D sets flex duct design)
- Lawrence Berkeley National Laboratory: Abushakra, Walker and Sherman, Compression Effects on Pressure Loss in Flexible HVAC Ducts (HVAC&R Research, 2004)
- Lawrence Berkeley National Laboratory: Sherman and Walker duct sealant tests (August 17, 1998): one duct tape survived three months, eleven failed within days
- U.S. DOE Building America Solution Center: Duct Leakage Tests (25 Pa, CFM25)
- ICC: 2021 International Residential Code, Chapter 16, Section M1601.1 (duct design to ACCA Manual D, the manufacturer's instructions or other approved methods)
- ICC: 2021 IECC, Section R403.3.1 (ducts outside conditioned space R-8 at 3 inches and larger, R-6 smaller)
- ACCA: 400 CFM Per Ton, Or Is It? (Matt Akins, February 4, 2021; 350 CFM/ton for hot, humid climates and 450 for drier ones)
- NIST SP 811, Appendix B.9 (ton of refrigeration = 12,000 Btu per hour)
- ENERGY STAR: When is it time to replace? (a noisy system can mean an undersized duct system or a problem with the indoor coil)
- Poerschke (IBACOS) for U.S. DOE, Room Return Path Sensitivity, NREL/TP-5600-79887 (July 2021): closing doors raises return airflow resistance
- U.S. DOE: Right-Size Heating and Cooling Equipment, DOE/GO-102002-1490 (insist on documented ACCA Manual J calculations)
Related Articles
Ductwork Sizing Calculator: BTU to CFM and CFM to Duct Size
Calculator • 9 min read
Flexible vs Rigid Ductwork: Pros, Cons, and When to Use Each
Comparison • 11 min read
Duct Leakage Testing: Why It Matters and How to Fix Leaky Ducts
Explainer • 14 min read
Cold Air Return Vents: How They Work, Placement and Sizing
Guide • 15 min read
Is Air Duct Cleaning Worth It? What the EPA Says
Analysis • 11 min read