Three ways to cleaner indoor air
The EPA lists three strategies, and controlling the sources is usually the most effective[4]. Most home heating and cooling systems don't bring fresh air into the house, so ventilating takes open windows and doors or fans that vent outdoors[4].
Air cleaners and filters supplement the first two[5]. Most aren't designed to remove gases[4], and the EPA suggests a filter rated at least MERV 13, or as high as the system takes[5].
Indoor Air Quality Facts
Browse by Category
Indoor Air Quality
Indoor air quality monitors, testing, and improvement solutions
UV Lights for HVAC Systems: Do They Work?
What UV-C lights in an HVAC system do: coil-mounted vs. air-stream units, what the EPA says about effectiveness, ozone and safety concerns, maintenance, and when they're worth considering.
Carbon Monoxide Detector Placement: Where and How Many You Need
Complete guide to carbon monoxide detector placement: where to put them, how many per home, mounting height, code requirements, standard vs low-level monitors, and the CO exposure levels that trigger alarms.
How to Improve Indoor Air Quality: 10 Methods Ranked
A practical, ranked guide to improving indoor air quality: ten methods from a MERV 13 filter upgrade to whole-house systems, with the effort each takes and what each one actually does.
VOCs in Your Home: Sources, Health Effects, and How to Reduce Them
What VOCs are, the household products and materials that release them, health effects per the EPA, how long off-gassing lasts, testing, and the steps that actually lower levels.
Whole-House Ventilation Systems: ERV vs HRV Explained
How whole-house ventilation works: exhaust, supply and balanced systems, HRV vs. ERV, how much fresh air a home needs under ASHRAE 62.2, and which system suits your climate.
Indoor Air Quality Testing: What to Test, How, and What the Results Mean
Which indoor air tests matter (radon, carbon monoxide, particles, humidity, VOCs, mold), the EPA's guidance and action levels, home monitors vs. lab tests, and what to do with results.
Start here
Sources & References
- EPA: Report on the Environment, Indoor Air Quality (about 90 percent of time spent indoors; some pollutants often 2 to 5 times higher indoors than typical outdoor concentrations)
- EPA: Mold Course Chapter 2 (indoor relative humidity below 60 percent, ideally 30 to 50 percent)
- EPA: What is a HEPA filter? (at least 99.97% of particles 0.3 microns across, the most penetrating particle size)
- EPA: Improving Indoor Air Quality (three strategies: source control, usually the most effective; ventilation, since most home heating and cooling systems do not bring fresh air into the house; air cleaners, generally not designed to remove gaseous pollutants)
- EPA: Guide to Air Cleaners in the Home (a filter rated at least MERV 13, or as high as the system will accommodate; HVAC filters filter only while the system runs)