R-value measures how well insulation resists heat flow: the higher the number, the less heat passes through.[2] Choosing the right level comes down to your climate zone and where the insulation goes, and ENERGY STAR publishes recommended levels for both.[1]

ENERGY STAR recommends R-60 for an uninsulated attic in climate zones 4 through 8,[1] R-49 in zones 2 and 3,[1] and R-30 in zone 1.[1] Heat flow is inversely proportional to R-value, so going from R-19 to R-49 cuts the heat lost through a ceiling by about 61% (1 − 19 ÷ 49 = 0.61); seal air leaks first, which the DOE says saves 10% to 20%[2] on heating and cooling bills.

Two ceilings show heat rising through R-19 and R-49 insulation, R-49 letting through about 61% less, beside ENERGY STAR's attic targets: R-30 in zone 1, R-49 in zones 2 and 3, R-60 in zones 4 to 8.
ENERGY STAR's levels for an uninsulated attic, and why a higher R-value loses less heat.

What R-value means

The DOE defines an insulation's R-value as a measure of its resistance to heat flow, and says the higher the R-value, the greater the insulating effectiveness.[2] R-value is measured in °F·h·ft²/Btu, the unit NIST lists for thermal insulance,[7] so the heat flowing through a surface, in Btu per hour, = area × temperature difference ÷ R-value. Doubling the R-value therefore halves the heat lost.

Under the FTC's R-value Rule, manufacturers must label insulation packages with the R-value,[8] and an installer must give you a receipt showing the coverage area, thickness and R-value of what was installed.[9]

How to find your climate zone

The recommendations are keyed to the IECC climate zones, which run from very hot to subarctic; the 50 states span zone 1 to zone 8.[3] Zone 1 gets the least insulation, and zones 4 through 8 share the highest attic level,[1] which is why the attic target climbs from R-30 to R-60 and then holds there.

Several zones also split by moisture: A is humid, B is dry and C is marine.[3] The ICC defines marine climates by a coldest-month mean between 27°F and 65°F,[11] a warmest-month mean under 72°F,[11] at least 4 months averaging over 50°F[11] and a dry summer. That's why the table lists zone 4 twice: the attic target is R-60 in both, but the floor recommendation is R-19 in 4A and 4B and R-30 in 4C.[1]

Zones are assigned by county, not by state, so one state can span more than one zone.[3] Look up your county on our climate zone map to place yourself on the table.

ENERGY STAR's recommended levels for retrofitting existing wood-framed buildings, based on the 2021 IECC,[1] for attics and floors:

Climate zoneAttic, if uninsulatedAttic with 3 to 4 inches alreadyFloor
1
R30
R25
R13
2
R49
R38
R13
3
R49
R38
R19
4A and 4B
R60
R49
R19
4C, 5 and 6
R60
R49
R30
7 and 8
R60
R49
R38
Source: ENERGY STAR, Recommended Home Insulation R-Values, recommended insulation levels for retrofitting existing wood-framed buildings. ENERGY STAR notes the guidance is based on the 2021 International Energy Conservation Code, Residential Provisions, Table R402.1.3. View the ENERGY STAR table.

Walls, basements and crawlspaces

When the siding comes off an uninsulated wood-frame wall, ENERGY STAR recommends drilling holes in the sheathing and blowing insulation into the empty cavity before the new siding goes on.[1] It then adds insulative sheathing under the new siding: R5 in zone 3, and R5 to R10 in zones 4 through 8.[1] An already-insulated 2x4 wall in zones 4 through 8 gets R10 of sheathing.[1]

For basement and crawlspace walls, ENERGY STAR recommends R5 sheathing or an R13 batt in zone 3,[1] R10 sheathing or an R13 batt in zones 4A and 4B,[1] and R15 sheathing or an R19 batt in zones 4C and 5 through 8.[1] ENERGY STAR presents all of these as the levels that are cost-effective for each climate and location in the home.[1]

How many inches each R-value takes

The DOE lists closed-cell spray foam at R-6.5 for 1 inch and open-cell at R-12.6 for 3.5 inches,[4] about R-3.6 per inch (12.6 ÷ 3.5 = 3.6). Dividing a target R-value by those figures gives a rough foam depth, as in the table below.

TargetOpen-cell foam (about R-3.6 per inch)Closed-cell foam (R-6.5 per inch)
R-30
about 8.3 in
about 4.6 in
R-38
about 10.6 in
about 5.8 in
R-49
about 13.6 in
about 7.5 in
R-60
about 16.7 in
about 9.2 in
How this was calculated: each depth is the target R-value divided by the DOE figure, R-3.6 per inch for open-cell (12.6 divided by 3.5) and R-6.5 per inch for closed-cell; for example R-49 divided by 6.5 is about 7.5 inches. It is a straight-line estimate, since the R-value per inch of some products drops as they get thicker.

Treat those depths as an estimate, not a spec. The FTC bars sellers from quoting an R-value per inch unless tests show it doesn't drop as the product gets thicker, and a seller who lists a range must add: "The thicker the insulation, the lower the R-value per inch."[10] Check the R-value at your actual thickness on the product's label or fact sheet.

Batts and loose fill are sold by R-value instead. By FTC rule, a batt label shows the R-value, length, width, thickness and square feet in the package, and a loose-fill label gives the installed and settled thickness and the bags per 1,000 square feet[8] for R-13, R-19, R-22, R-30, R-38 and R-49.[8]

How much heat each level stops

For example, take 1,000 sq ft of ceiling with a 40°F difference between the room and the attic:

R-valueHeat flow
R-19
about 2,105 BTU per hour
R-38
about 1,053 BTU per hour
R-49
about 816 BTU per hour
R-60
about 667 BTU per hour
How this was calculated: heat flow as area times temperature difference divided by R-value, here 1,000 square feet of ceiling at a 40 degree Fahrenheit difference, so 1,000 times 40 divided by the R-value

Over a heating season of 4,500 heating degree days, the site's calculator assumption for zone 4 and inside the 3,600 to 5,400 range the ICC gives that zone,[11] going from R-19 to R-49 cuts that ceiling's heat loss from about 5.7 to 2.2 million Btu (1,000 × 4,500 × 24 ÷ 19 = 5,684,000; 1,000 × 4,500 × 24 ÷ 49 = 2,204,000). With an assumed 95% AFUE gas furnace at EIA's 2025 U.S. residential gas price, $15.34 per thousand cubic feet,[5] about $1.48 a therm at 1,036 Btu a cubic foot,[6] that's about $54 a year (3,480,000 ÷ 0.95 ÷ 100,000 = 36.6 therms; 36.6 × $1.48 = $54), before counting summer cooling. With a heat pump, the saving depends on your electricity rate and the pump's efficiency.

Each added step saves less than the one before it. The jump from R-19 to R-38 cuts 2,105 − 1,053 = about 1,052 BTU per hour, the next step to R-49 saves only 1,053 − 816 = about 237, and R-49 to R-60 saves 816 − 667 = about 149. ENERGY STAR's attic targets top out at R-60, even in the coldest zones.[1]

Seal air leaks first

The DOE says sealing uncontrolled air leaks can save 10% to 20%[2] on heating and cooling bills, and its guidance is to consider adding insulation after you complete air sealing.[2] EPA estimates that air sealing plus insulation in attics, floors over crawl spaces and basements saves homeowners an average of 15%[12] on heating and cooling costs.

Before a house is sealed tighter, ENERGY STAR warns that sealing can make combustion appliances like water heaters backdraft, and it recommends inspection and testing by a home energy professional to find combustion safety issues first.[13]

Signs your home is under-insulated

ENERGY STAR lists the attic problems that air sealing and insulation address: drafty rooms, hot and cold rooms with uneven temperatures, high heating or cooling bills, and ice dams on the roof in winter.[13] For a basement or crawlspace it adds a cold floor in winter and pests.[13] It also says 9 out of 10[12] homes in the U.S. are under-insulated.

Ice dams are a cold-climate tell. The DOE's Building America Solution Center says they need snow on the roof, a poorly air-sealed or poorly insulated attic and freezing temperatures, and can form with as little as 2 inches of snow:[14] heated air escaping into the attic warms the roof deck, melts the snow above, and the water refreezes at the cold eaves. Its first fix is to seal the air leaks into the attic, around wiring, light fixtures, plumbing stacks, flues, attic hatches and top plates.[14]

Below-grade spots count too. For crawl spaces, read the crawl space moisture guide before you insulate.

Frequently asked questions

What R-value do I need in my attic?

ENERGY STAR recommends R-60 for an uninsulated attic in zones 4 through 8,[1] R-49 in zones 2 and 3,[1] and R-30 in zone 1.[1] If you already have 3 to 4 inches,[1] its targets are R-49, R-38 and R-25 for the same groups.[1]

Is a higher R-value always better?

Higher stops more heat, but each step saves less than the last: R-19 to R-38 halves the heat flow (19 ÷ 38 = 0.5), while R-38 to R-60 cuts it by about 37% more (1 − 38 ÷ 60 = 0.37).

What insulation has the highest R-value per inch?

Of the materials in the DOE's Guide to Home Insulation, closed-cell spray foam and polyisocyanurate board rate highest, R-6.5 for 1 inch,[4] against R-5 for extruded polystyrene and R-3.8 to R-4.4 for expanded polystyrene.[4] Under the FTC's rule, a seller can quote R-value per inch only if tests show it doesn't drop as the product gets thicker.[10]

Should I seal air leaks before adding insulation?

Yes. The DOE's guidance is to consider adding insulation after you complete air sealing,[2] which on its own can save 10% to 20%[2] on heating and cooling bills.

How many inches of insulation do I need for R-49?

As a straight-line estimate from the DOE's figures, closed-cell spray foam at R-6.5 per inch[4] reaches R-49 in about 7.5 inches (49 ÷ 6.5 = 7.5), and open-cell at about R-3.6 per inch in about 13.6 inches (49 ÷ 3.6 = 13.6). For loose fill, the FTC requires the bag label to show the installed thickness and bags per 1,000 square feet at R-49.[8]

How do I know which climate zone I am in?

Zones are set by county, so one state can span more than one zone.[3] Look up your county on the climate zone map, then read the recommended R-value off the table above.

What are the signs that my home is under-insulated?

ENERGY STAR's list for attics is drafty rooms, uneven temperatures between rooms, high heating or cooling bills and ice dams in winter; for basements and crawlspaces it adds cold floors in winter.[13]

Sources & References

  1. ENERGY STAR: Recommended Home Insulation R-Values (cost-effective levels for retrofitting existing wood-framed buildings; based on the 2021 IECC, Table R402.1.3)
  2. U.S. DOE: Energy Saver Guide (2022): sealing uncontrolled air leaks can save 10%–20% on heating and cooling bills (p. 6); after you complete air sealing, consider whether you need to add insulation; the higher the R-value, the greater the insulating effectiveness (p. 7)
  3. PNNL-33270: Guide to Determining Climate Zones by County (2021 IECC), for the U.S. DOE
  4. U.S. DOE: Guide to Home Insulation (DOE/EE-0340, October 2010): open-cell spray foam R-12.6 at 3.5 inches; closed-cell spray foam and polyisocyanurate board R-6.5 at 1 inch; extruded polystyrene R-5; expanded polystyrene R-3.8 to 4.4
  5. U.S. EIA: U.S. Price of Natural Gas Delivered to Residential Consumers, annual (2025: $15.34 per thousand cubic feet; released October 30, 2026)
  6. U.S. EIA: Heat Content of Natural Gas Delivered to Consumers (U.S., 2025: 1,036 Btu per cubic foot)
  7. NIST Special Publication 811, Appendix B.9: thermal insulance, °F·h·ft²/Btu (1 °F·h·ft²/Btu = 0.1761102 m²·K/W)
  8. 16 CFR 460.12 (Cornell LII), FTC R-value Rule, Labels: batts show R-value, length, width, thickness and square feet; loose fill shows thickness, coverage and bags per 1,000 square feet at R-values of 13, 19, 22, 30, 38 and 49
  9. 16 CFR 460.17 (Cornell LII), FTC R-value Rule: installers must give customers a receipt showing the coverage area, thickness and R-value installed
  10. 16 CFR 460.20 (Cornell LII), FTC R-value Rule, R-value per inch claims: allowed only if tests prove the R-value per inch doesn't drop with thickness; a range must carry "The thicker the insulation, the lower the R-value per inch"
  11. ICC: 2021 IECC Code and Commentary, Chapter 3 sample (PDF), Table C301.3 (climate zone 4: 3,600 to 5,400 heating degree days, 65°F base; marine: coldest month 27°F to 65°F, warmest under 72°F, at least 4 months over 50°F, dry summer)
  12. ENERGY STAR: Why Seal and Insulate? (EPA estimates an average 15% saving on heating and cooling costs from air sealing and insulating attics, floors over crawl spaces and basements; 9 out of 10 U.S. homes are under-insulated)
  13. ENERGY STAR: Identify the Problems You Want to Fix (attic: drafty rooms, uneven temperatures, high bills, ice dams; basement and crawlspace: cold floors, pests; combustion safety testing before air sealing)
  14. U.S. DOE Building America Solution Center: Attic Air Sealing, Insulating, and Ventilating for Ice Dam Prevention (ice dams can form with as little as 2 inches of snow; seal attic air leaks first)