A furnace heats air and pushes it through the house with a blower and ducts[4]. Cold air at the registers means the blower is moving air the burner didn't heat, and the first checks are ones you can make in a few minutes.

Start at the thermostat: the DOE advises keeping the fan switch on Auto[3]; on On, the blower keeps running between heating cycles. Then check the filter: "A dirty filter will slow down air flow and make the system work harder"[1]. If the burner itself won't light or stay lit, that is the controls and burner check ENERGY STAR puts on a contractor's list[2]; if you smell gas, leave the house first.

Diagram of a furnace with five numbered checks for cold air: thermostat fan on Auto, a dirty filter, closed registers or blocked returns, a burner that won't light, and the condensate drain, plus a gas smell warning.
Work through the checks in order; a burner that won't light or a gas smell calls for a contractor or the gas company.

Quick checks you can make

  • Mode and setpoint. The thermostat should be on Heat, set above the room's temperature.
  • Fan on Auto. The DOE's Energy Saver Guide says to leave the fan switch on Auto unless an indoor air quality professional set it to run continuously[3].
  • The filter. ENERGY STAR says "Check your filter every month, especially during heavy use months (winter and summer). If the filter looks dirty after a month, change it."[1]
  • Registers and returns. Open closed supply registers and clear furniture off return grilles. DOE's Building America Solution Center warns that "Too many closed dampers can lead to inadequate airflow through the furnace/air handler and result in HVAC equipment malfunction"[5].

Work through it in order

  1. Fan on On? Switch it to Auto[3]. If the cool air between cycles stops, that was the cause.
  2. Dirty filter or blocked airflow? Replace the filter and open the registers[1]. DOE notes that "A clogged filter restricts airflow through the unit"[6], and ENERGY STAR that a dirty filter "can increase energy costs and damage your equipment, leading to early failure"[2].
  3. Cold air at only some registers? The furnace may be heating fine and the problem is in the ducts: ENERGY STAR lists "Improper equipment operation, duct problems or inadequate insulation" as causes of rooms that are too hot or too cold[7].
  4. Burner won't light, or lights and goes out? Call a contractor. ENERGY STAR's heating check covers "gas (or oil) connections, gas pressure, burner combustion and heat exchanger," and the system's controls and starting cycle[2].
  5. High-efficiency furnace with water around it? Condensing furnaces produce condensate, and ENERGY STAR's check-up includes the condensate drain, since "A plugged drain can cause water damage in the house"[2]. See furnace leaking water.

The warm-up and the blower

The blower moves the air; the burner heats it[4]. If a furnace's blower runs while its burner is off, whether because of the fan setting or a control that has shut the burner down, the air at the registers comes out at roughly room temperature.

A contractor's check-up looks at exactly this: ENERGY STAR's list includes checking "the starting cycle of the equipment to assure the system starts, operates, and shuts off properly"[2].

Flame sensing, ignition and safety controls

Furnaces differ here by age and model. DOE describes older furnaces with natural draft and a "continuous pilot light," and mid-efficiency units with an exhaust fan and "electronic ignition (no pilot light)"[4].

A burner that won't light or won't stay lit points to the burner, its gas supply or its controls, and the troubleshooting steps and fault codes are specific to each furnace's model and manual. ENERGY STAR puts the burner, the gas connections and the controls on the contractor's list[2], so book the visit rather than working near the gas valve.

Condensate on high-efficiency furnaces

High-efficiency furnaces condense their flue gases in a second heat exchanger[4], so they make water that has to drain away. The 2021 International Residential Code allows a water-level detection device that shuts off the equipment if the primary condensate drain is blocked, as one of the protections against overflow[8]. On a system with one, a clogged drain can stop the equipment until the drain is cleared.

If you have a heat pump

Heat pump air is cooler than furnace air by design. Natural Resources Canada puts a heat pump's supply air at 25 to 45°C[9] and a furnace's at 55 to 60°C[9]. In Fahrenheit that is about 77 to 113°F against 131 to 140°F (°F = °C × 1.8 + 32).

In defrost, a heat pump switches to cooling mode to melt frost off its outdoor coil and can cool the air in the ducts, and supplementary heat may run during defrost to offset it[9]. A short spell of cool air in winter can be normal; see heat pumps in cold weather.

When to stop and get help

  • You smell gas. The CPSC says to "leave your home immediately and contact local gas authorities from outside the home," and not to operate lights, phones or other electronics before leaving[10].
  • A carbon monoxide alarm sounds. "Never ignore an alarm when it sounds. Get outside immediately, then call 911."[10]
  • The burner won't light or stay lit after you've checked the thermostat and filter[2].
  • Cold air continues with a clean filter and open registers.

A cracked heat exchanger is one reason a contractor may shut a furnace down; see cracked heat exchanger.

Frequently asked questions

Why is my furnace blowing cold air?

The causes you can check yourself are the thermostat fan set to On instead of Auto[3], a dirty filter restricting airflow[6], and closed registers or blocked returns[5]. If those are fine, the burner and controls need a contractor[2].

Can a dirty filter make a furnace blow cold air?

A clogged filter restricts airflow through the unit[6], and ENERGY STAR says a dirty filter can damage equipment and lead to early failure[2]. Replace it, then see whether the heat returns.

Should I set the furnace fan to On or Auto?

Auto, unless an indoor air quality professional set it to run continuously, the DOE says[3]. On keeps the blower running between heating cycles.

Should I turn off my furnace if it's blowing cold air?

If the burner won't stay lit, yes, and call a contractor. If you smell gas, leave the house and call from outside[10].

How do I clean a furnace flame sensor?

We don't give steps for it. The flame sensor sits in the burner area next to the gas valve, the procedure depends on the furnace's model and manual, and ENERGY STAR assigns the burner and controls to a contractor's check-up[2].

Is my heat pump broken if it blows cold air in winter?

Not necessarily. Its supply air runs cooler than a furnace's[9], and during defrost it switches to cooling mode and can cool the duct air[9]. If the outdoor unit stays iced over or cool air continues, have it checked.