A furnace's heat exchanger is the metal chamber that keeps the burning fuel and its exhaust apart from the air your blower sends through the house. A crack or hole breaks that separation, which is why it's treated as a safety problem first and a repair second.
DOE says furnace heat exchangers "mix combustion gases with house air when they leak", and that those gases "can cause carbon monoxide poisoning"[4]. If a CO alarm sounds or anyone has headache, dizziness or nausea, CPSC says to get outside to fresh air immediately and then call 911[2]. Otherwise, turn the furnace off and have a heating professional check the heat exchanger and test for carbon monoxide[4].
Why it's dangerous
Carbon monoxide is colorless and odorless, and the CDC says it "kills without warning"[1]. Each year more than 400 Americans[1] die from unintentional CO poisoning not linked to fires, more than 100,000 visit an emergency department[1], and more than 14,000 are hospitalized[1]. People who are asleep "can die from CO poisoning before they have symptoms"[1].
DOE suggests that every home have a working carbon monoxide alarm[4], and CPSC says to install one on every level and outside sleeping areas[2]. See the carbon monoxide detector guide.
How a leak behaves
A 1996 survey[5] for Canada's national housing agency, CMHC, describes two ways a damaged heat exchanger causes trouble[5]. Combustion products can leak out into the circulating house air, or house air can leak in and keep the exhaust from venting properly[5].
Most manufacturers design the heat exchanger so the house air is at a higher pressure than the combustion products, so "in the event of a small crack, air will leak into the heat exchanger rather than combustion products leaking out"[5]. That inward air isn't harmless: the report says enough of it "can also disturb the flame pattern causing high levels of Carbon Monoxide"[5].
Warning signs
- A carbon monoxide alarm, or symptoms CPSC lists: headache, dizziness, weakness, nausea, vomiting, sleepiness and confusion[2]. The CDC notes CO symptoms are often described as flu-like[1].
- A burner flame that misbehaves. ENERGY STAR says a cracked heat exchanger "causes improper burner operation"[3], and air pushed in through a crack can disturb the flame pattern[5].
- Cracks or holes a technician finds in the combustion chamber, a check on DOE's list for forced-air systems[4].
A CO alarm alone doesn't prove the heat exchanger is the source. The CDC lists many sources of CO, including furnaces, cars and trucks, small engines, stoves, gas ranges, fireplaces and grills[1], so the source still has to be found.
What causes cracks and holes
The CMHC survey names cracks, "through-the-wall perforation as a result of corrosion", and leaks as the hazards[5]. It also says a heat exchanger "may show no signs of cracks but may leak due to either a design or construction flaw"[5].
Not every crack is dangerous. The same report quotes a major manufacturer expecting its heat exchangers "to develop some innocuous stress relieving cracks after the first few months of operation"[5], which is why the evidence matters more than the word "crack".
Maintenance limits the damage. ENERGY STAR says a dirty filter "can increase energy costs and damage your equipment, leading to early failure"[3], and its heating check-up covers burner combustion and the heat exchanger[3].
How a technician confirms it
There is no single standard field test. The CMHC survey of 41 North American gas utilities[5] found almost all of them inspect the heat exchanger and the flame pattern by eye, then run a more detailed test if they suspect a leak[5]. It identified some 15 different test methods[5], found only about 15%[5] of respondents used a quantitative one, and concluded that "no one test method stands out as being a clear candidate for development"[5].
The methods it lists include carbon dioxide or oxygen tests, smoke bombs, salt spray, tracer gas and odor tracing, and most of the other tests utilities reported were carbon monoxide monitoring in the circulating air[5]. DOE's maintenance list for forced-air systems has the technician check the combustion chamber for cracks and test for carbon monoxide[4].
What a technician should show you
The CMHC report warns that the call is left to the person doing the inspection, and that "many furnaces may be being 'red-tagged' unnecessarily"[5]. Before you agree to replace a furnace, ask for the evidence:
- A photo or video of the crack or hole and where it sits on the heat exchanger.
- Carbon monoxide readings in parts per million, from the exhaust and, where taken, the circulating air[5].
- The flame check, shown to you live, since air pushed in through a crack can disturb the flame pattern[5].
If you're shown no image and no measurement, get a second opinion before spending anything.
What to do
- If a CO alarm sounds or anyone feels ill, get outside to fresh air immediately, then call 911[2].
- Turn the furnace off if a leak is suspected, and use safe temporary heat.
- Have it inspected by a heating professional, who should check the heat exchanger and test for carbon monoxide[4].
- Check the warranty paperwork for the heat exchanger, including whether it covers labor.
- Decide repair or replacement with the evidence in hand.
Repair or replace
The choice is between replacing the heat exchanger and replacing the furnace. Age is the first thing to weigh: ENERGY STAR suggests considering replacement once a furnace is more than 15 years old[6].
A new furnace also changes the efficiency. Federal rules have required at least 80% AFUE[7] for non-weatherized gas furnaces made since November 19, 2015[7], while DOE puts high-efficiency condensing furnaces, with a second heat exchanger and sealed combustion, at 90% to 98.5% AFUE[4]. ENERGY STAR says a certified furnace is about 15% more efficient[6] than a conventional one.
The furnace guide covers that choice, and how long HVAC systems last covers age.
Preventing it
The CDC says to have your heating system, water heater and other fuel-burning appliances serviced by a qualified technician every year[1]. ENERGY STAR says to inspect, clean or change air filters once a month[3] and to check the heating system in the fall[3]; see how often to change your HVAC filter.
Frequently asked questions
Is a cracked heat exchanger dangerous?
It can be. DOE says a leaking furnace heat exchanger mixes combustion gases with house air, which can cause carbon monoxide poisoning[4]. Turn the furnace off and have it inspected.
What are the signs of a cracked heat exchanger?
A CO alarm or CO symptoms[2], and a burner flame that misbehaves[3]. A technician confirms it by inspecting the heat exchanger and testing for carbon monoxide[4].
Can a cracked heat exchanger be repaired?
The fixes are a new heat exchanger or a new furnace. Not every crack is a hazard: the CMHC report describes harmless stress-relief cracks[5], so ask for the evidence first.
What causes a heat exchanger to crack?
The CMHC report names cracks, corrosion that perforates the metal, and design or construction flaws that let it leak[5]. ENERGY STAR adds that a dirty filter can damage equipment and lead to early failure[3].
How long can I keep running the furnace while I wait for a repair?
Treat a suspected leak as a reason to stop using the furnace. Keep working CO alarms on every level and outside sleeping areas[2], and if one sounds, get outside and call 911[2].
Does a carbon monoxide alarm alone prove the heat exchanger is cracked?
No. It tells you carbon monoxide is present, and the CDC lists many fuel-burning sources besides furnaces, including cars, small engines, stoves and gas ranges[1]. The source still has to be found by inspection.
Should I replace the whole furnace or just the heat exchanger?
Check the furnace's age and its warranty. ENERGY STAR suggests considering replacement once a furnace is more than 15 years old[6]; on a newer furnace still under a heat exchanger warranty, replacing the part can make sense.
Sources & References
- CDC: Carbon Monoxide (CO) Poisoning Basics (kills without warning; more than 400 deaths, more than 100,000 emergency department visits and more than 14,000 hospitalizations a year; symptoms; sleeping people can die before symptoms; sources including furnaces; service heating systems every year)
- CPSC: Carbon Monoxide Information Center (symptoms; if you suspect CO poisoning, get outside to fresh air immediately, then call 911; alarms on every level and outside sleeping areas)
- ENERGY STAR: Maintenance Checklist (heating check-up covers burner combustion and the heat exchanger; a cracked heat exchanger causes improper burner operation; a dirty filter can damage equipment; filters monthly; heating checked in the fall)
- U.S. DOE Energy Saver: Furnaces and Boilers (archived copy of a retired page, Wayback Machine snapshot of October 1, 2025): leaking furnace heat exchangers mix combustion gases with house air; CO alarm in every home; professional maintenance list; AFUE classes
- Canada Mortgage and Housing Corporation: Survey of North American Furnace Heat Exchanger Integrity Test Methods, prepared by the Canadian Gas Research Institute (February 1996), via Government of Canada Publications
- ENERGY STAR: When is it time to replace? (furnace or boiler more than 15 years old; ENERGY STAR furnace about 15% more efficient than a conventional one)
- 10 CFR 430.32(e) (Cornell LII): furnace AFUE minimums, 80.0% for non-weatherized gas furnaces made on or after November 19, 2015
Related Articles
Carbon Monoxide Detector Placement: Where and How Many You Need
How-to • 11 min read
Furnaces: A Homeowner's Guide to Gas, Electric and Oil
Guide • 14 min read
How Often Should You Change Your HVAC Filter?
Guide • 8 min read
Furnace Leaking Water? Causes and Fixes
Troubleshooting • 11 min read
HVAC Maintenance Checklist: Seasonal DIY Guide
Guide • 13 min read