Bare soil under a house gives off water vapor, and in a crawl space that vapor can condense on the floor joists and feed mold and rot.[1] A plastic ground cover stops it at the source, once rain and groundwater are kept out.[2]
A crawl space moisture barrier is a polyethylene sheet, 6-mil or thicker in DOE's guides,[2] laid over the whole dirt floor with the seams overlapped and taped and the edges run up the walls.[1] DOE says to install it whether the crawl space is vented or not.[1] Full encapsulation goes further: sealed vents, insulated walls and a way to dry the air, which the 2021 International Residential Code[5] requires in an unvented crawl space.
What the barrier does
Moisture can migrate into the soil under a crawl space and enter it "as liquid water or water vapor from the soil, which can then condense on floor joists," says DOE's Building America Solution Center.[1] Its fix is "a heavy polyethylene plastic capillary break that is sealed to the walls and piers," installed "regardless of whether the crawlspace is vented or unvented."[1] The same sheet "will also help keep soil gases from entering the home."[1]
The humidity target is the EPA's: below 60% relative humidity,[9] ideally between 30% and 50%.[9] Moisture in a crawl space promotes "mold and rot along floor joists and rim joists," in DOE's words.[1]
Fix the water first
A ground cover handles vapor from the soil, not flooding. In vented crawl spaces, DOE calls bulk water "the dominant source of crawlspace moisture," coming from poor grading, missing perimeter drainage or irrigation.[1] Its water management guide says those problems must be dealt with first "to ensure that the crawlspace will be dry and remain dry once enclosed."[2]
DOE's list of fixes, roughly from outside in:
- Regrade so the ground slopes away from the house, and make patios, walks and driveways slope away too.[2]
- Install drain pipe around the exterior footings, draining to daylight or a drywell.[2]
- Fix gutters and downspouts so they carry rainwater away from the foundation.[2]
- Put a sump pump in low spots, in a plastic pit 2 to 3 feet deep[2] with holes drilled in the bottom and a gasketed, tight-fitting lid.[2]
- If the crawl space floor sits below the outside grade, provide perimeter drainage.[3]
Liner materials and thickness
DOE's water management guide calls for "6-mil or thicker" polyethylene,[2] and its retrofit checklist for "a minimum 6-mil-thick polyethylene sheeting."[3] A mil is 0.001 inch,[13] so 6-mil sheeting is 6 × 0.001 = 0.006 inch thick.
For an unvented crawl space, the 2021 IRC asks for a continuous Class I vapor retarder,[5] the class rated at 0.1 perm or less,[6] and the code lists sheet polyethylene as Class I.[7] It names a material class, not a thickness.[5]
For wear, DOE's capillary break guide lists three options "for added durability": a second sheet laid over the first once other work is done, "a vinyl runner or extra plastic over any areas that will get traffic, such as a service path to the furnace," or a concrete slab "2 or more inches thick"[1] over the sealed sheet. Neither the code sections nor the DOE guides on this page call for a sheet thicker than that minimum, so a heavier or reinforced liner is a durability choice.
Seams, edges and piers
The guides differ slightly on how far to lap the sheet, and the code sets the minimum for an unvented crawl space. Taping every seam is common to all of them.
| Seam overlap | Up the walls | Up interior piers | |
|---|---|---|---|
DOE water management guide | 6 to 12 inches, taped | 8 to 12 inches, or preferably to the outside ground level | 8 to 12 inches |
DOE capillary break guide | 12 inches, taped | At least 6 inches, or to the outside ground level | At least 4 inches |
DOE unvented crawlspace guide | 12 inches, sealed with adhesive and tape | To within 4 inches of the top of the wall | Not stated |
DOE retrofit checklist | 6 to 12 inches, taped | At least 6 inches up walls and footings | Not stated |
2021 IRC, R408.3 (unvented) | 6 inches, sealed or taped | At least 6 inches up the stem wall | Not stated |
Fasten the edges with pressure-treated wood furring strips or other mechanical fasteners; DOE says they can be sealed to the wall with fiberglass mesh tape and duct mastic.[1] Clear vegetation and organic material off the ground before the sheet goes down.[3]
To estimate how much sheeting to buy, add the floor area to the strip that runs up the walls. For example, a 25 by 40 foot crawl space has 25 × 40 = 1,000 sq ft of floor and a perimeter of 2 × (25 + 40) = 130 feet, so a 12-inch lap up the walls adds 130 × 1 = 130 sq ft, for 1,130 sq ft before the seam overlaps.
Ground cover vs. full encapsulation
A vented crawl space keeps its foundation vents, and the cover goes on the floor. When the ground is covered with a Class I vapor retarder, the 2021 IRC cuts the net vent area required from 1 sq ft per 150 sq ft of floor[5] to 1 per 1,500 sq ft.[5] For a 1,000 sq ft crawl space that is 1,000 ÷ 150 = 6.7 sq ft of vent area over bare soil, or 1,000 ÷ 1,500 = 0.67 sq ft with the cover.
An unvented crawl space, the kind people call encapsulated, drops the vents. In their place the 2021 IRC requires a continuous Class I vapor retarder, with joints overlapped 6 inches[5] and sealed or taped and the edges at least 6 inches up the stem wall,[5] plus one way to dry the space:
- a continuously running exhaust fan at 1 cfm per 50 sq ft of floor;[5]
- conditioned supply air at 1 cfm per 50 sq ft;[5]
- use of the crawl space as a plenum, allowed in existing houses;[5] or
- "dehumidification sized in accordance with manufacturer's specifications."[5]
For a 1,000 sq ft crawl space, the air options come to 1,000 ÷ 50 = 20 cfm of exhaust or supply air.
| Vented crawl space (R408.2) | Unvented crawl space (R408.3) | |
|---|---|---|
Foundation vents | 1 sq ft of net opening per 150 sq ft of floor, or 1 per 1,500 sq ft with a Class I ground cover | Not required |
Ground cover | A Class I cover lowers the vent area required | Continuous Class I vapor retarder, joints overlapped 6 inches and sealed or taped, edges at least 6 inches up the stem wall |
Drying the air | Outdoor air through the vents | One of: exhaust fan at 1 cfm per 50 sq ft, conditioned supply air at 1 cfm per 50 sq ft, plenum (existing houses), or a dehumidifier sized to the manufacturer's specifications |
In humid climates, DOE says, warm outdoor air coming in through crawl space vents can condense on cooler framing, and "building scientists recommend building insulated, unvented crawlspaces."[1] Its unvented crawlspace guide lists the payoffs: less condensation on cold floor or rim joists, warmer floors, HVAC equipment and plumbing protected from freezing in cold climates, and a space "less likely to harbor pests."[4]
A DOE-funded field study compared 12 all-electric houses[8] with the same floor plan on one cul-de-sac in the Southeast: closed crawl spaces against vented ones that also had polyethylene covering the whole ground. The closed crawl spaces were "substantially drier" and cut space-conditioning energy use 15 to 18% a year[8] on sub-metered data alone, a figure the authors say normalizing for base load may reduce.
Closing a vented crawl space
DOE's retrofit checklist for converting a vented crawl space to an unvented one runs in this order:
| Stage | What DOE's checklist calls for |
|---|---|
Before work | Inspect for bulk water, moisture and pest damage; verify foundation drainage and waterproofing; add perimeter drainage if the floor is below outside grade |
Access | A 16 by 24 inch airtight, insulated door in the wall, or an 18 by 24 inch access panel through the floor |
Ground | Remove old insulation, replace rotted wood, clear vegetation and organic material; lay 6-mil polyethylene lapped 6 to 12 inches, tape every seam, tear and hole, and run it 6 inches up the walls and footings |
Walls | Block and seal the vents; air seal and insulate cripple walls, rim joists and foundation walls to at least the 2012 IECC |
Air | HVAC supply and return air at 1 cfm per 50 sq ft of crawl space floor |
Checks | A combustion safety test if a natural-draft furnace or water heater is in the crawl space; watch for water intrusion; a radon test kit for the homeowner |
Gas appliances need care in a closed crawl space. DOE's unvented guide says not to install low-efficiency heating that draws its combustion air from the crawl space, and to use direct-vent sealed-combustion furnaces or heat pumps instead.[4] After sealing, the checklist calls for a combustion safety test on any natural-draft equipment to make sure there is no back-drafting or spillage.[3]
Humidity control after encapsulation
A closed crawl space still needs its air dried, by supply air, an exhaust fan or a dehumidifier, as the code options above show.[5] Aim for the EPA range of below 60%, ideally 30% to 50%,[9] and check it with a humidity meter, which the EPA calls "a small, inexpensive ($10-$50) instrument."[10]
If a dehumidifier does the drying, the 2021 IRC asks only that it be sized to the manufacturer's specifications.[5] Every ENERGY STAR dehumidifier has a built-in humidistat that cycles the unit to hold the humidity you set.[11] In a cool crawl space, ENERGY STAR warns that below 65°F[11] frost can form on the coils, and suggests a model designed for low temperatures.[11]
For sizing and power use, see what size dehumidifier do I need, the dehumidifier guide and dehumidifier running cost.
Radon
The ground cover also slows soil gas, and DOE suggests going further. Its capillary break guide recommends considering a passive radon vent that "collects soil gasses under the plastic and vents them through the roof,"[1] and its unvented crawlspace guide says a radon venting system should be installed under the vapor barrier.[4] Test after the work: the EPA recommends fixing a home at 4 pCi/L or higher.[12]
What it costs
None of the federal sources on this page publishes a price for crawl space ground covers or encapsulation, so this page gives no dollar figures. Scope sets the price, so ask for written, itemized quotes that list each of these items:
- The liner, its seam tape and wall fasteners, sized from the floor area plus the strip up the walls.
- Any drainage work: regrading, gutters, footing drains or a sump pump.
- For encapsulation: sealed vents, wall and rim joist insulation, an insulated access door, and the drying method (supply air, an exhaust fan, or a dehumidifier with its drain and outlet).
- Options: a second sheet, a runner over the service path, a thin slab, or a radon vent.
Common mistakes
- Covering standing water or an active leak instead of fixing the drainage first.[2]
- Leaving vegetation or other organic material under the sheet.[3]
- Leaving seams untaped or edges loose instead of lapped up the walls and fastened.[1]
- Closing the vents without a drying method, which the 2021 IRC requires in an unvented crawl space.[5]
- Leaving tears from the work unrepaired; DOE says to inspect the sheet after insulating and seal any rips.[4]
- Sealing in a natural-draft furnace or water heater without a combustion safety test.[3]
Frequently asked questions
What thickness vapor barrier should I use in a crawl space?
At least 6-mil polyethylene,[3] the minimum in DOE's retrofit checklist. In an unvented crawl space the 2021 IRC asks for a continuous Class I vapor retarder, and sheet polyethylene is Class I.[7] Where people will crawl, DOE suggests a second sheet, a vinyl runner over the service path, or a concrete slab 2 inches or thicker over the sheet.[1]
Do I need a vapor barrier in a vented crawl space?
DOE says yes: the plastic ground cover "should be installed regardless of whether the crawlspace is vented or unvented."[1] Under the 2021 IRC, a Class I ground cover also cuts the vent area required from 1 sq ft per 150 sq ft of floor[5] to 1 per 1,500.[5]
Is crawl space encapsulation worth it?
In a humid climate, DOE's guidance points that way: "building scientists recommend building insulated, unvented crawlspaces."[1] In the DOE-funded Southeast study, closed crawl spaces were substantially drier and cut space-conditioning energy use 15 to 18%[8] on sub-metered data. Fix any water problem first, so the crawl space stays dry once it is closed.[2]
Should I close my crawl space vents?
Only as part of converting to an unvented crawl space. The 2021 IRC then requires a continuous Class I vapor retarder and a drying method: supply air, an exhaust fan, use as a plenum in an existing house, or a dehumidifier.[5]
Does a crawl space moisture barrier stop mold?
It removes the soil as a moisture source, which DOE ties to mold and rot on floor and rim joists.[1] Bulk water from grading or drainage problems still has to be fixed,[1] and the EPA's target is indoor humidity below 60%, ideally 30% to 50%.[9]
Does a vapor barrier help with radon?
It helps keep soil gases out, and DOE suggests a passive radon vent that collects gas under the plastic.[1] Test afterward; the EPA recommends fixing a home at 4 pCi/L or higher.[12]
Sources & References
- U.S. DOE Building America Solution Center: Capillary Break at Crawlspace Floors, Polyethylene Lapped Up Walls and Piers or Secured in the Ground (updated 2017-07-25; 6-mil or thicker, seams overlapped 12 inches, at least 6 inches up walls and 4 up piers, durability options, install whether vented or unvented, radon vent)
- U.S. DOE Building America Solution Center: Water Management of Existing Crawlspace Floor (updated 2015-02-09; grading, footing drains, gutters, sump pit 2 to 3 feet deep, 6-mil or thicker sheet lapped 6 to 12 inches and 8 to 12 inches up walls)
- U.S. DOE Building America Solution Center: Home Improvement Expert checklist, Vented to Unvented Crawl Space (minimum 6-mil sheeting, 16 by 24 inch access, 1 CFM per 50 sq ft, combustion safety test, radon test kit)
- U.S. DOE Building America Solution Center: Unvented, Insulated Crawlspaces (updated 2021-09-23; benefits, radon venting under the vapor barrier, repair tears, sealed-combustion equipment)
- 2021 International Residential Code, Chapter 4: Foundations, Section R408 Under-Floor Space (R408.2 vent area, R408.3 unvented crawl spaces)
- 2021 International Residential Code, Chapter 2: Definitions, R202 (Class I vapor retarder, 0.1 perm or less)
- 2021 International Residential Code, Chapter 7: Wall Covering, Table R702.7(1) (sheet polyethylene is a Class I vapor retarder)
- Davis et al., North Carolina Advanced Energy Corporation for the U.S. DOE: A Field Study Comparison of the Energy and Moisture Performance Characteristics of Ventilated Versus Sealed Crawl Spaces in the South (June 22, 2005; 12 houses; 15 to 18% space-conditioning savings on sub-metered data)
- EPA: Mold course, chapter 2 (indoor humidity below 60%, ideally 30 to 50%)
- EPA: A Brief Guide to Mold, Moisture and Your Home (humidity meter $10 to $50)
- ENERGY STAR: Dehumidifiers (built-in humidistat; frost below 65°F, low-temperature models)
- EPA: A Citizen's Guide to Radon (EPA 402/K-12/002, revised 2016; fix at 4 pCi/L or higher)
- NIST Special Publication 811, Appendix B.8: Factors for Units Listed Alphabetically (mil = 0.001 inch)
Related Articles
Dehumidifiers: Sizing, Types and Running Costs
Guide • 13 min read
How Much Does It Cost to Run a Dehumidifier? (Calculator)
Calculator • 10 min read
Ideal Indoor Humidity Level: What Should It Be by Season? (Chart)
Explainer • 10 min read
How to Identify Mold in Your Home: Signs, Smells and What to Do
Guide • 12 min read
How to Improve Indoor Air Quality: 10 Methods Ranked
How-to • 15 min read