What you pay for heat comes down to two things you can look up: what your fuel costs where you live, and how much of it your equipment turns into heat. This page prices the same amount of heat, a million Btu delivered into the home, for every state and the main heating fuels, from the U.S. Energy Information Administration's latest prices[1].
Where a home can get natural gas, the cheapest way to heat it at those prices is a 95% gas furnace[9]: it makes heat for less than the other fuels and a heat pump at ENERGY STAR's minimum rating[8] in 45 states and DC[1][2], and that heat pump wins in Arkansas, Florida, Georgia, Hawaii and Louisiana. Without gas, the heat pump wins almost everywhere EIA prices the other fuels: against heating oil in all 21 states[5] it covers, and against propane in 37 of the 38[4], all but Illinois.
Pick your state to see its numbers. The break-even COP is the one to watch: a heat pump whose seasonal COP beats it costs less to run than the fuel it replaces.
Heating cost in your state
A million Btu of heat by fuel, from EIA prices
What a million Btu of heat costs by fuel
At U.S. average prices, a million Btu of heat costs $15.59[2] from a 95% gas furnace[9], $23.32[1] from a heat pump at a seasonal COP of 2.29[8], $32.42[4] from a 95% propane furnace, $47.45[5] from an 87% oil furnace[9] and $53.31[1] from electric resistance heat. Each figure is the fuel price divided by how much heat the fuel holds and by the equipment's efficiency; the method section below works one example for every fuel.
The state table below repeats the calculation with each state's own prices. Propane and heating oil show "n/a" where EIA's weekly survey has no price for the state: it covers propane in 38 states[4] and heating oil in 21[5].
| State | Natural gas | Propane | Heating oil | Electric resistance | Heat pump | Cheapest |
|---|---|---|---|---|---|---|
| United States | $15.59 | $32.42 | $47.45 | $53.31 | $23.32 | Natural gas |
| Alabama | $17.91 | $42.68 | n/a | $48.45 | $21.19 | Natural gas |
| Alaska | $13.81 | n/a | n/a | $80.25 | $35.10 | Natural gas |
| Arizona | $19.10 | n/a | n/a | $44.84 | $19.62 | Natural gas |
| Arkansas | $19.83 | $29.96 | n/a | $40.59 | $17.76 | Heat pump |
| California | $22.67 | n/a | n/a | $94.81 | $41.47 | Natural gas |
| Colorado | $11.03 | $28.91 | n/a | $49.59 | $21.69 | Natural gas |
| Connecticut | $17.18 | $50.78 | $45.20 | $80.42 | $35.18 | Natural gas |
| Delaware | $16.26 | $45.72 | $48.84 | $52.99 | $23.18 | Natural gas |
| District of Columbia | $17.00 | n/a | n/a | $73.15 | $32.00 | Natural gas |
| Florida | $26.19 | $59.47 | n/a | $44.70 | $19.55 | Heat pump |
| Georgia | $20.83 | $38.73 | n/a | $45.66 | $19.97 | Heat pump |
| Hawaii | $60.13 | n/a | n/a | $136.69 | $59.79 | Heat pump |
| Idaho | $7.79 | $31.92 | n/a | $38.51 | $16.85 | Natural gas |
| Illinois | $11.30 | $23.20 | n/a | $56.33 | $24.64 | Natural gas |
| Indiana | $11.43 | $31.45 | $46.48 | $49.94 | $21.85 | Natural gas |
| Iowa | $10.54 | $20.60 | $43.11 | $42.79 | $18.72 | Natural gas |
| Kansas | $15.00 | $26.39 | n/a | $44.93 | $19.65 | Natural gas |
| Kentucky | $14.28 | $33.74 | $46.79 | $41.38 | $18.10 | Natural gas |
| Louisiana | $17.95 | n/a | n/a | $38.92 | $17.03 | Heat pump |
| Maine | $19.03 | $42.40 | $47.19 | $88.89 | $38.88 | Natural gas |
| Maryland | $16.35 | $45.53 | $50.34 | $62.54 | $27.36 | Natural gas |
| Massachusetts | $25.59 | $43.97 | $47.10 | $88.72 | $38.81 | Natural gas |
| Michigan | $10.84 | $29.28 | $45.84 | $64.13 | $28.05 | Natural gas |
| Minnesota | $10.96 | $25.05 | $43.98 | $48.48 | $21.21 | Natural gas |
| Mississippi | $17.13 | $36.78 | n/a | $43.90 | $19.21 | Natural gas |
| Missouri | $15.37 | $26.59 | n/a | $42.47 | $18.58 | Natural gas |
| Montana | $8.91 | $26.20 | n/a | $41.85 | $18.31 | Natural gas |
| Nebraska | $11.36 | $21.20 | $42.41 | $38.19 | $16.71 | Natural gas |
| Nevada | $13.27 | n/a | n/a | $39.13 | $17.12 | Natural gas |
| New Hampshire | $18.85 | $44.84 | $47.63 | $79.48 | $34.77 | Natural gas |
| New Jersey | $14.41 | $47.39 | $48.58 | $70.75 | $30.95 | Natural gas |
| New Mexico | $10.14 | n/a | n/a | $45.52 | $19.91 | Natural gas |
| New York | $17.93 | $44.00 | $49.55 | $85.49 | $37.40 | Natural gas |
| North Carolina | $16.52 | $43.31 | $46.62 | $43.96 | $19.23 | Natural gas |
| North Dakota | $9.55 | $21.35 | n/a | $36.99 | $16.18 | Natural gas |
| Ohio | $13.73 | $32.40 | $47.30 | $55.22 | $24.15 | Natural gas |
| Oklahoma | $14.58 | $28.51 | n/a | $41.06 | $17.96 | Natural gas |
| Oregon | $16.36 | n/a | n/a | $45.40 | $19.86 | Natural gas |
| Pennsylvania | $15.28 | $37.64 | $46.08 | $62.25 | $27.23 | Natural gas |
| Rhode Island | $22.14 | $47.46 | $47.11 | $85.40 | $37.36 | Natural gas |
| South Carolina | $17.18 | n/a | n/a | $46.81 | $20.47 | Natural gas |
| South Dakota | $9.65 | $23.08 | n/a | $43.23 | $18.91 | Natural gas |
| Tennessee | $12.16 | $39.09 | n/a | $40.24 | $17.60 | Natural gas |
| Texas | $20.12 | $36.94 | n/a | $46.92 | $20.53 | Natural gas |
| Utah | $10.23 | $29.45 | n/a | $38.72 | $16.94 | Natural gas |
| Vermont | $18.08 | $45.93 | $46.67 | $70.40 | $30.79 | Natural gas |
| Virginia | $16.88 | $43.66 | $47.73 | $49.91 | $21.83 | Natural gas |
| Washington | $16.92 | n/a | n/a | $42.41 | $18.55 | Natural gas |
| West Virginia | $13.36 | n/a | n/a | $45.84 | $20.05 | Natural gas |
| Wisconsin | $10.78 | $24.53 | $43.56 | $55.95 | $24.47 | Natural gas |
| Wyoming | $11.72 | n/a | n/a | $41.30 | $18.06 | Natural gas |
Does a heat pump beat your fuel?
A heat pump's seasonal COP is the heat it delivers over a winter divided by the electricity it uses. The break-even COP is the point where its heat costs exactly as much as the other fuel's: below it the other fuel is cheaper, above it the heat pump is. It depends only on your two fuel prices and the other appliance's efficiency, so it holds for any heat pump in any house.
Against a new 95% gas furnace[9], the break-even runs from 1.71 in Florida to 5.91 in Michigan[1][2], and it is 3.42 at U.S. average prices[1][2]. Against an 80% furnace[10], which burns more gas for the same heat, it drops to 2.88 nationally[2]. Against propane it tops out at 2.43 in Illinois[4], and against heating oil at 1.88 in both Maine and Massachusetts[5].
Electric resistance heat turns all of its electricity into heat[13], a COP of 1[13]. So where the break-even falls under 1[13], even electric baseboard or an electric furnace costs less than the fuel: propane in Florida[4], and heating oil in Iowa, Kentucky, Nebraska and North Carolina[5].
| State | Vs. 95% gas furnace | Vs. 80% gas furnace | Vs. propane furnace | Vs. oil furnace |
|---|---|---|---|---|
| United States | 3.42 | 2.88 | 1.64 | 1.12 |
| Alabama | 2.70 | 2.28 | 1.14 | n/a |
| Alaska | 5.81 | 4.89 | n/a | n/a |
| Arizona | 2.35 | 1.98 | n/a | n/a |
| Arkansas | 2.05 | 1.72 | 1.35 | n/a |
| California | 4.18 | 3.52 | n/a | n/a |
| Colorado | 4.50 | 3.79 | 1.72 | n/a |
| Connecticut | 4.68 | 3.94 | 1.58 | 1.78 |
| Delaware | 3.26 | 2.74 | 1.16 | 1.08 |
| District of Columbia | 4.30 | 3.62 | n/a | n/a |
| Florida | 1.71 | 1.44 | 0.75 | n/a |
| Georgia | 2.19 | 1.85 | 1.18 | n/a |
| Hawaii | 2.27 | 1.91 | n/a | n/a |
| Idaho | 4.94 | 4.16 | 1.21 | n/a |
| Illinois | 4.99 | 4.20 | 2.43 | n/a |
| Indiana | 4.37 | 3.68 | 1.59 | 1.07 |
| Iowa | 4.06 | 3.42 | 2.08 | 0.99 |
| Kansas | 2.99 | 2.52 | 1.70 | n/a |
| Kentucky | 2.90 | 2.44 | 1.23 | 0.88 |
| Louisiana | 2.17 | 1.83 | n/a | n/a |
| Maine | 4.67 | 3.93 | 2.10 | 1.88 |
| Maryland | 3.82 | 3.22 | 1.37 | 1.24 |
| Massachusetts | 3.47 | 2.92 | 2.02 | 1.88 |
| Michigan | 5.91 | 4.98 | 2.19 | 1.40 |
| Minnesota | 4.42 | 3.73 | 1.94 | 1.10 |
| Mississippi | 2.56 | 2.16 | 1.19 | n/a |
| Missouri | 2.76 | 2.33 | 1.60 | n/a |
| Montana | 4.70 | 3.96 | 1.60 | n/a |
| Nebraska | 3.36 | 2.83 | 1.80 | 0.90 |
| Nevada | 2.95 | 2.48 | n/a | n/a |
| New Hampshire | 4.22 | 3.55 | 1.77 | 1.67 |
| New Jersey | 4.91 | 4.13 | 1.49 | 1.46 |
| New Mexico | 4.49 | 3.78 | n/a | n/a |
| New York | 4.77 | 4.01 | 1.94 | 1.73 |
| North Carolina | 2.66 | 2.24 | 1.01 | 0.94 |
| North Dakota | 3.87 | 3.26 | 1.73 | n/a |
| Ohio | 4.02 | 3.39 | 1.70 | 1.17 |
| Oklahoma | 2.82 | 2.37 | 1.44 | n/a |
| Oregon | 2.77 | 2.34 | n/a | n/a |
| Pennsylvania | 4.07 | 3.43 | 1.65 | 1.35 |
| Rhode Island | 3.86 | 3.25 | 1.80 | 1.81 |
| South Carolina | 2.72 | 2.29 | n/a | n/a |
| South Dakota | 4.48 | 3.77 | 1.87 | n/a |
| Tennessee | 3.31 | 2.79 | 1.03 | n/a |
| Texas | 2.33 | 1.96 | 1.27 | n/a |
| Utah | 3.79 | 3.19 | 1.31 | n/a |
| Vermont | 3.89 | 3.28 | 1.53 | 1.51 |
| Virginia | 2.96 | 2.49 | 1.14 | 1.05 |
| Washington | 2.51 | 2.11 | n/a | n/a |
| West Virginia | 3.43 | 2.89 | n/a | n/a |
| Wisconsin | 5.19 | 4.37 | 2.28 | 1.28 |
| Wyoming | 3.52 | 2.97 | n/a | n/a |
What COP a real heat pump reaches
HSPF2 is the Btu of heat a heat pump delivers per watt-hour over DOE's test heating season[8], so ENERGY STAR's minimum of 7.8 HSPF2 for split systems[8] works out to a seasonal COP of 7.8 ÷ 3.412 = 2.29 (3,412 Btu in a kWh[6]). That is the COP the tables use for the heat pump.
Cold weather pulls COP down. Natural Resources Canada puts typical air-source COPs at 2.0 to 5.4 at 8°C[14] and 1.1 to 3.7 at −8°C[14], so the same heat pump runs a higher seasonal COP in Georgia than in Minnesota. Compare your heat pump's expected COP with your state's break-even, and see our COP explainer and cold-weather guide.
Fuel prices by state and a typical gas-heated home
Electricity is EIA's residential average for January to September 2026[1], preliminary in its November release. Natural gas is EIA's 2025[2] residential average, or the 2024 average[2] in Connecticut, Maine, Maryland, North Carolina, Rhode Island and South Carolina, which have no figure for 2025[2]. Propane and heating oil are EIA's residential prices for the week of November 16, 2026[4], excluding taxes.
The last two columns show what a typical gas-heated home pays. EIA's 2020 household survey found that homes heating with gas used 44.9 million Btu of it for space heating on average[7]. At the U.S. average price that gas costs about $665 a year (44.9 × $14.81 = $665), from $212 in Florida to $1,352 in Rhode Island[7], whose figure uses EIA's 2024 price[2].
| State | Electricity (cents/kWh) | Natural gas ($/thousand cu ft) | Propane ($/gal) | Heating oil ($/gal) | Gas for heat (million Btu) | Yearly cost of that gas |
|---|---|---|---|---|---|---|
| United States | 18.19 | 15.34 | 2.817 | 5.717 | 44.9 | $665 |
| Alabama | 16.53 | 17.56 | 3.708 | n/a | 28.6 | $487 |
| Alaska | 27.38 | 12.96 | n/a | n/a | 94.5 | $1,240 |
| Arizona | 15.30 | 18.58 | n/a | n/a | 16.1 | $292 |
| Arkansas | 13.85 | 19.25 | 2.603 | n/a | 44.3 | $834 |
| California | 32.35 | 22.01 | n/a | n/a | 17.6 | $379 |
| Colorado | 16.92 | 11.17 | 2.512 | n/a | 52.6 | $551 |
| Connecticut | 27.44 | 16.83 (2024) | 4.412 | 5.446 | 48.8 | $797 |
| Delaware | 18.08 | 15.97 | 3.972 | 5.885 | 40.6 | $627 |
| District of Columbia | 24.96 | 16.68 | n/a | n/a | 28.9 | $467 |
| Florida | 15.25 | 25.48 | 5.167 | n/a | 8.5 | $212 |
| Georgia | 15.58 | 20.42 | 3.365 | n/a | 37.0 | $732 |
| Hawaii | 46.64 | 52.38 | n/a | n/a | n/a | n/a |
| Idaho | 13.14 | 7.69 | 2.773 | n/a | 51.1 | $378 |
| Illinois | 19.22 | 11.25 | 2.016 | n/a | 66.3 | $712 |
| Indiana | 17.04 | 11.49 | 2.732 | 5.601 | 59.3 | $644 |
| Iowa | 14.60 | 10.61 | 1.790 | 5.194 | 56.8 | $569 |
| Kansas | 15.33 | 14.81 | 2.293 | n/a | 50.9 | $726 |
| Kentucky | 14.12 | 14.23 | 2.931 | 5.638 | 43.0 | $583 |
| Louisiana | 13.28 | 17.39 | n/a | n/a | 20.8 | $355 |
| Maine | 30.33 | 18.95 (2024) | 3.684 | 5.686 | 49.3 | $891 |
| Maryland | 21.34 | 16.14 (2024) | 3.956 | 6.066 | 43.8 | $680 |
| Massachusetts | 30.27 | 25.06 | 3.820 | 5.675 | 48.9 | $1,189 |
| Michigan | 21.88 | 10.92 | 2.544 | 5.523 | 72.7 | $749 |
| Minnesota | 16.54 | 10.98 | 2.176 | 5.299 | 64.1 | $667 |
| Mississippi | 14.98 | 16.65 | 3.195 | n/a | 34.2 | $557 |
| Missouri | 14.49 | 14.94 | 2.310 | n/a | 56.7 | $828 |
| Montana | 14.28 | 8.99 | 2.276 | n/a | 60.5 | $512 |
| Nebraska | 13.03 | 11.40 | 1.842 | 5.110 | 51.4 | $555 |
| Nevada | 13.35 | 13.14 | n/a | n/a | 25.1 | $317 |
| New Hampshire | 27.12 | 18.61 | 3.896 | 5.739 | 44.0 | $788 |
| New Jersey | 24.14 | 14.21 | 4.117 | 5.854 | 60.6 | $830 |
| New Mexico | 15.53 | 9.83 | n/a | n/a | 38.7 | $373 |
| New York | 29.17 | 17.58 | 3.823 | 5.971 | 46.2 | $787 |
| North Carolina | 15.00 | 16.42 (2024) | 3.763 | 5.617 | 35.7 | $560 |
| North Dakota | 12.62 | 9.50 | 1.855 | n/a | 69.1 | $627 |
| Ohio | 18.84 | 13.85 | 2.815 | 5.700 | 62.3 | $812 |
| Oklahoma | 14.01 | 14.38 | 2.477 | n/a | 42.6 | $590 |
| Oregon | 15.49 | 16.71 | n/a | n/a | 43.2 | $672 |
| Pennsylvania | 21.24 | 15.04 | 3.270 | 5.552 | 57.2 | $830 |
| Rhode Island | 29.14 | 21.66 (2024) | 4.123 | 5.676 | 64.3 | $1,352 |
| South Carolina | 15.97 | 16.91 (2024) | n/a | n/a | 29.1 | $475 |
| South Dakota | 14.75 | 9.86 | 2.005 | n/a | 53.5 | $491 |
| Tennessee | 13.73 | 11.84 | 3.396 | n/a | 43.8 | $506 |
| Texas | 16.01 | 19.42 | 3.209 | n/a | 23.5 | $449 |
| Utah | 13.21 | 10.19 | 2.559 | n/a | 46.3 | $450 |
| Vermont | 24.02 | 18.00 | 3.990 | 5.624 | 47.1 | $809 |
| Virginia | 17.03 | 16.79 | 3.793 | 5.751 | 44.0 | $706 |
| Washington | 14.47 | 17.62 | n/a | n/a | 46.4 | $746 |
| West Virginia | 15.64 | 13.80 | n/a | n/a | 59.9 | $760 |
| Wisconsin | 19.09 | 10.74 | 2.131 | 5.249 | 59.7 | $611 |
| Wyoming | 14.09 | 11.74 | n/a | n/a | 63.0 | $702 |
The 2020 survey year[7] sets how much gas those homes burned; a colder winter burns more. For your own house, our heating cost calculator and furnace vs heat pump calculator take your square footage and climate.
How the numbers are calculated
Every figure on this page is one division chain, worked here at U.S. average prices:
- Natural gas: $15.34 per thousand cubic feet[2] ÷ 1.036 million Btu in a thousand cubic feet[3] = $14.81 per million Btu of gas, and $14.81 ÷ 0.95 = $15.59 of heat.
- Electricity: 1,000,000 ÷ 3,412 = 293.08 kWh in a million Btu[6], so 18.19 cents[1] × 293.08 = $53.31 of resistance heat; a heat pump with a seasonal COP of 7.8 ÷ 3.412 = 2.286[8] makes the same heat for $53.31 ÷ 2.286 = $23.32.
- Propane: 1,000,000 ÷ 91,452 = 10.935 gallons in a million Btu[6], so $2.817[4] × 10.935 = $30.80 of propane, and $30.80 ÷ 0.95 = $32.42 of heat.
- Heating oil: 1,000,000 ÷ 138,500 = 7.22 gallons[6], so $5.717[5] × 7.22 = $41.28 of oil, and $41.28 ÷ 0.87 = $47.45 of heat.
- Break-even COP: $53.31 ÷ $15.59 = 3.42 against a 95% gas furnace.
The efficiencies come from federal rules and ENERGY STAR. Gas and propane furnaces are at 95% AFUE[12], which DOE calls readily achievable by modern condensing furnaces[12] and which is ENERGY STAR's minimum in the South (97% in the North)[9]; federal rules count propane as gas[11]. The older furnace is at 80%[10], the federal minimum for non-weatherized gas furnaces made since November 19, 2015[10], and the oil furnace is at ENERGY STAR's minimum of 87%[9].
Each state's gas price is converted with its own heat content, which ranges from 917 Btu per cubic foot[3] in Hawaii to 1,096 in Washington[3]. It prices the fuel only: equipment, installation and the cooling a heat pump also provides are left out. This page is updated when EIA publishes new prices.
Download the data
The three state tables are one CSV file with the prices, the cost of heat for every fuel, the break-even COPs and the typical gas-heated home, rebuilt from the same data whenever the prices change. You can use it with credit.
One row for each state and the District of Columbia, plus the U.S. average: residential electricity, natural gas, propane and heating oil prices from the U.S. Energy Information Administration, what a million Btu of heat delivered into the home costs with each fuel, the cheapest fuel, the seasonal COP a heat pump needs to beat each furnace, and what a typical gas-heated home's heating gas costs at the latest price. Efficiencies: gas and propane furnaces 95%, an older gas furnace 80%, oil furnace 87%, electric resistance 100%, heat pump COP 2.29 (7.8 HSPF2).
Columns
- state
- State, the District of Columbia, or United States for the national average
- electricity_
cents_ per_ kwh - Average residential electricity price, January to September 2026, cents per kWh (EIA Electric Power Monthly, Table 5.6.B; 2026 values preliminary)
- natural_
gas_ usd_ per_ thousand_ cubic_ feet - Average price of natural gas delivered to residential consumers, dollars per thousand cubic feet (EIA)
- natural_
gas_ price_ year - Year of that gas price: 2025, or 2024 where EIA reports no 2025 value
- natural_
gas_ btu_ per_ cubic_ foot - Heat content of natural gas delivered to consumers in the state, 2025 (EIA)
- propane_
usd_ per_ gallon - Residential propane price, week of November 16, 2026, excluding taxes (EIA); blank where EIA has no price for the state
- heating_
oil_ usd_ per_ gallon - Residential heating oil price, week of November 16, 2026, excluding taxes (EIA); blank where EIA has no price for the state
- heat_
cost_ gas_ 95_ usd_ per_ mmbtu - Dollars per million Btu of heat from a 95% AFUE gas furnace (calculated)
- heat_
cost_ propane_ 95_ usd_ per_ mmbtu - Dollars per million Btu of heat from a 95% AFUE propane furnace at 91,452 Btu a gallon (calculated)
- heat_
cost_ oil_ 87_ usd_ per_ mmbtu - Dollars per million Btu of heat from an 87% AFUE oil furnace at 138,500 Btu a gallon (calculated)
- heat_
cost_ electric_ resistance_ usd_ per_ mmbtu - Dollars per million Btu of heat from electric resistance heat, 293.08 kWh per million Btu (calculated)
- heat_
cost_ heat_ pump_ usd_ per_ mmbtu - Dollars per million Btu of heat from a heat pump at a seasonal COP of 2.29, ENERGY STAR's 7.8 HSPF2 minimum for split systems (calculated)
- cheapest_
fuel - The lowest-cost fuel at these efficiencies, among those the state has prices for
- breakeven_
cop_ vs_ gas_ 95 - Seasonal COP at which a heat pump matches a 95% gas furnace (calculated)
- breakeven_
cop_ vs_ gas_ 80 - Seasonal COP at which a heat pump matches an 80% gas furnace (calculated)
- breakeven_
cop_ vs_ propane_ 95 - Seasonal COP at which a heat pump matches a 95% propane furnace (calculated)
- breakeven_
cop_ vs_ oil_ 87 - Seasonal COP at which a heat pump matches an 87% oil furnace (calculated)
- recs_
2020_ gas_ space_ heating_ mmbtu - Natural gas used for space heating per household that heats with gas, 2020, million Btu (EIA RECS Table CE4.6NG.ST; Hawaii withheld)
- typical_
gas_ home_ heating_ gas_ usd_ per_ year - That gas at the state's latest gas price, dollars a year (calculated)
License: free to use, share and adapt under CC BY 4.0. Credit HVACBase with a link to this page, and name the original source: U.S. EIA, Electric Power Monthly, Table 5.6.B, U.S. EIA, natural gas residential prices by state, U.S. EIA, heat content of natural gas by state, U.S. EIA, Weekly Heating Oil and Propane Prices and U.S. EIA, 2020 RECS Table CE4.6NG.ST.
Cite as: HVACBase, "Heating cost by state," hvacbase.org/heating-cost-by-state, from U.S. Energy Information Administration prices (electricity January to September 2026; propane and heating oil week of November 16, 2026) and the 2020 Residential Energy Consumption Survey.
Embed the map on your site
Copy this HTML. It shows the full-size map with its legend and keeps the credit line.
<figure style="margin:0;max-width:800px">
<img src="https://www.hvacbase.org/images/heating/heating-cost-break-even-map.png" width="800" height="738" alt="Map of the seasonal COP a heat pump needs to beat a gas furnace, by state" style="width:100%;height:auto">
<figcaption>Map: <a href="https://www.hvacbase.org/heating-cost-by-state">HVACBase</a>, data from the U.S. Energy Information Administration</figcaption>
</figure>Frequently asked questions
What is the cheapest way to heat a house?
In most states it's a gas furnace: at these prices a 95% furnace[9] beats propane, oil, electric resistance and an ENERGY STAR minimum heat pump in 45 states and DC[1][2]. Without gas, a heat pump is usually the cheapest heat: at a seasonal COP of 2.29[8] it beats heating oil in every state EIA prices oil[5] and propane everywhere EIA prices it except Illinois[4].
Is a heat pump cheaper than gas in my state?
It is if your heat pump's seasonal COP beats your state's break-even in the table above. At U.S. average prices that's 3.42 against a 95% furnace[1][2] and 2.88 against an 80% one[1][2]; in Arkansas, Florida, Georgia, Hawaii and Louisiana it's under the 2.29 of an ENERGY STAR minimum heat pump[8].
Is propane cheaper than electric heat?
Cheaper than electric resistance heat, such as baseboard or an electric furnace, almost everywhere: a 95% propane furnace[9] makes heat for less in every state EIA prices propane except Florida[4]. Cheaper than a heat pump, mostly not: one at ENERGY STAR's minimum rating[8] costs less to run in 37 of those 38 states[4], all but Illinois. At U.S. average prices a million Btu of heat costs $32.42[4] from propane, $53.31[1] from resistance heat and $23.32[1] from the heat pump.
How much does it cost to heat a house per year?
For a typical gas-heated home, about $665 a year at the U.S. average gas price (44.9 million Btu × $14.81 = $665)[7]. The state table shows the same figure for each state, from $212 in Florida to $1,352 in Rhode Island[7].
Sources & References
- U.S. EIA: Electric Power Monthly, Table 5.6.B (average residential electricity price by state, year to date through September 2026, November 2026 release; 2026 values preliminary)
- U.S. EIA: Natural Gas Prices, average price of natural gas delivered to residential consumers by state, annual (2025; 2024 for CT, ME, MD, NC, RI and SC)
- U.S. EIA: Heat Content of Natural Gas Delivered to Consumers, by state, annual (2025)
- U.S. EIA: Weekly Heating Oil and Propane Prices, residential propane by state, week of November 16, 2026 (excluding taxes)
- U.S. EIA: Weekly Heating Oil and Propane Prices, residential heating oil by state, week of November 16, 2026 (excluding taxes)
- U.S. EIA: British thermal units (propane 91,452 Btu a gallon, heating oil 138,500, electricity 3,412 a kWh)
- U.S. EIA: 2020 Residential Energy Consumption Survey, Table CE4.6NG.ST, natural gas consumption by end use by state, averages (June 2023)
- ENERGY STAR: Heat Pump Key Product Criteria (split systems 7.8 HSPF2; HSPF2 in Btu per watt-hour over the heating season)
- ENERGY STAR: Furnaces Key Product Criteria (gas 95% AFUE U.S. South, 97% U.S. North; oil 87%)
- 10 CFR 430.32(e): furnace minimums (80% AFUE for non-weatherized gas furnaces made from November 19, 2015)
- 10 CFR 430.2: definitions ("Gas means either natural gas or propane")
- U.S. DOE: Final energy efficiency standards for residential furnaces (95% AFUE readily achievable by modern condensing furnaces)
- U.S. DOE Energy Saver: Electric Resistance Heating (archived copy of a retired page, Wayback Machine, October 1, 2025): 100% energy efficient in the sense that all the incoming electric energy is converted to heat
- Natural Resources Canada: Heating and cooling with a heat pump (typical air-source COPs at 8°C and -8°C)
Related Articles
Furnace vs Heat Pump: Which Is Better? (Cost and Climate Comparison)
Comparison • 11 min read
Gas vs Electric Heating: Which Is Cheaper? (Cost Calculator)
Comparison • 9 min read
Heating Cost Calculator: Compare Gas vs Electric vs Heat Pump Costs
Calculator • 11 min read
HVAC Cost by State: 2026 Electricity Rates, Efficiency Rules and Installation Costs
Guide • 9 min read
COP Explained: Coefficient of Performance of Heat Pumps
Guide • 12 min read