A portable generator keeps essentials running in an outage, and the CPSC names its primary hazards as "carbon monoxide (CO) poisoning from the toxic engine exhaust, electric shock or electrocution, fire and burns"[2]. Most generator incidents reported to the CPSC involve carbon monoxide from generators "used indoors or in partially-enclosed spaces"[2].
The CPSC counts an average of about 100 deaths a year[1] in the U.S. from carbon monoxide from portable generators. Run a generator outside only, at least 20 feet from the house[1], never on a porch or in a carport, with the exhaust pointed away from the home, and never inside a home, garage, basement, crawlspace or shed, even with doors and windows open. Keep battery-powered or battery-backup CO alarms working inside, and never plug a generator into a wall outlet.
The numbers
| Figure | Count |
|---|---|
U.S. deaths a year from CO poisoning from portable generators (average) | About 100 |
CO deaths associated with generators in 2020, the most of any product category | 92 |
U.S. deaths a year from unintentional CO poisoning not linked to fires, all sources | More than 400 |
Emergency department visits a year from that poisoning | More than 100,000 |
Hospitalizations a year from that poisoning | More than 14,000 |
The CDC's yearly figures cover every unintentional CO poisoning not linked to fires, and it names furnaces, portable generators and charcoal grills among the household sources[3]. The CPSC's average counts portable generators alone[1].
How generator carbon monoxide kills
"CO is called the invisible killer because it is colorless, odorless, and deadly," the CPSC says, and "CO poisoning from gasoline-powered portable generators can kill in minutes"[1]. In a confined space, generators "can produce high levels of CO within minutes," and "Even if you do not smell exhaust fumes, you may still be exposed to CO"[2].
The CPSC warns that it "can happen so quickly that exposed persons may become unconscious before recognizing symptoms such as nausea, dizziness or weakness"[1]. The CDC adds: "People who are sleeping, drunk, or under the influence of other substances can die from CO poisoning before they have symptoms."[3]
Symptoms
The CDC lists the most common symptoms as "headache, dizziness, weakness, upset stomach, vomiting, chest pain, and confusion," often described as "flu-like"[3]. "Infants, the elderly, and people with chronic heart disease, anemia, or breathing problems are more likely to get sick from CO."[3]
If you start to feel sick, dizzy or weak while a generator runs, the CPSC's instruction is to "get to fresh air RIGHT AWAY. DO NOT DELAY."[2] OSHA adds to seek medical attention and to stay out until trained, properly equipped personnel say the area is safe[4].
Where to run it
| Rule | Distance or place |
|---|---|
Outside only, away from the house (CPSC) | At least 20 feet |
Away from doors, windows and vents that could let CO indoors (CPSC) | At least 20 feet |
Away from any windows, doors and vents (CDC) | More than 20 feet |
Clear space on all sides and above (OSHA) | 3 to 4 feet |
Never | Inside a home, garage, basement, crawlspace, shed or other enclosed space |
Never | On a porch or in a carport |
- Never in an enclosed space. "NEVER operate a portable generator inside a home, garage, basement, crawlspace, shed or other enclosed spaces. Opening doors or windows will not provide enough ventilation to prevent the buildup of lethal levels of CO."[1] Deadly CO "can linger for hours, even after the generator has shut off"[2].
- Not on a porch or in a carport. "It's too close to the home and puts your family at risk of CO poisoning."[1]
- Aim the exhaust. "Direct the generator's exhaust away from your home and other buildings where someone can enter. Close windows and seal off vent openings that are near the generator or in the path of its exhaust."[1]
- Mind the openings. OSHA: "Do not use a generator outdoors if its placement near doors, windows, and vents could allow CO to enter and build up in occupied spaces."[4]
Read the danger label
"Danger labels are required on all portable generators manufactured or imported on or after May 14, 2007."[2]
The label shown in the CPSC's safety alert reads: "Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell."[2]
CO alarms and CO shut-off generators
- Where: battery-operated alarms or alarms with battery backup "on each level and outside separate sleeping areas at home"[1]. The CPSC prefers interconnected alarms, because "when one sounds, they all sound"[1].
- Which: CO alarms "should be certified to the requirements of the latest safety standards (UL 2034, IAS 6-96, or CSA 6.19.01)"[2].
- Testing: "Test CO and smoke alarms monthly to make sure they are working properly and replace batteries if needed."[1]
- Replacing: the CDC says to replace a CO detector "following the manufacturer's instructions or every 5 years"[3], and suggests one with a digital readout, which shows the highest CO level in the home[3].
- When it sounds: "Never ignore an alarm when it sounds. Get outside immediately, then call 911."[1]
When buying, the CPSC says to "Look for portable generators that have a CO shut-off safety feature."[1] The carbon monoxide detector guide covers alarm types and placement in more depth.
Connecting to the house
Never plug a generator into a wall outlet. The CPSC's safety alert:
NEVER try to power the house wiring by plugging the generator into a wall outlet, a practice known as "backfeeding." This is extremely dangerous and presents an electrocution risk to utility workers and neighbors served by the same utility transformer. It also bypasses some of the built-in household circuit protection devices.[2]
OSHA: "Never attach a generator directly to the electrical system of a structure (home, office, trailer, etc.) unless a qualified electrician has properly installed the generator with a transfer switch."[4] Without one, it "can energize wiring systems for great distances. This creates a risk of electrocution for utility workers and others in the area."[4]
For a permanent standby generator, Wisconsin's consumer protection agency says only "a qualified professional, such as a licensed electric contractor," should install it, recommends a double-pole, double-throw transfer switch and says to tell your electric company[6]. See how many amps a generator produces for outlet and cord ratings.
Grounding
OSHA: "Make sure a generator is properly grounded and the grounding connections are tight. Consult the manufacturer's instructions for proper grounding methods."[4] Follow the grounding method in your generator's manual, and for a connection to house wiring, ask the electrician who installs the transfer switch.
Cords and GFCI protection
- Outdoor-rated, big enough: "heavy-duty extension cords that are specifically designed for outdoor use. Make sure the wattage rating for each cord exceeds the total wattage of all appliances connected to it."[2]
- Undamaged: "Check that the entire length of each cord is free of cuts or tears and that the plug has all three prongs."[2] Protect a cord that passes through a window or doorway from being pinched or crushed[2].
- Long enough: the cords should let the generator sit outdoors, far away from windows, doors and vents[2].
- Grounded: OSHA says to plug appliances "directly into the generator using the manufacturer's supplied cords or extension cords that are grounded (3-pronged)"[4]. "Do not use underrated cords"[4]; replace them with properly rated cords that use heavier-gauge wire[4].
- Not overloaded: "Do not overload a generator"[4], OSHA says, since that can overheat it and create a fire hazard[4].
- GFCIs: "Use ground fault circuit interrupters (GFCIs), especially where electrical equipment is used in or around wet or damp locations. GFCIs shut off power when an electrical current is detected outside normal paths."[4]
Fuel and refueling
- Refuel cold: "Before refueling the generator, turn it off and let it cool down. Gasoline spilled on hot engine parts could ignite."[2] OSHA adds that generators "remain hot for long periods after they are stopped"[4].
- Store fuel outside living areas: "Never store fuel for your generator in the home. Gasoline, propane, kerosene, and other flammable liquids should be stored outside of living areas in properly-labeled, non-glass safety containers. Do not store them near a fuel-burning appliance, such as a natural gas water heater in a garage."[2]
- Keep vapors from flames: OSHA says to keep fuel containers away from "flame producing and heat generating devices (such as the generator itself, water heaters, cigarettes, lighters, and matches)," because "Escaping vapors or vapors from spilled materials can travel long distances to ignition sources."[4]
Rain and snow
The CPSC: "Follow the portable generator manufacturer's instructions about electrical shock hazards in inclement weather, which may include use of an NFPA-rated non-combustible generator tent or may advise to wait until rain or snow passes."[1] Generators "pose a risk of shock and electrocution, especially if they are operated in wet conditions"[2].
To keep it dry without moving it indoors, the CPSC's alert says: "Operate the generator under an open, canopy-like structure on a dry surface where water cannot reach it or puddle or drain under it. Dry your hands, if wet, before touching the generator."[2] OSHA adds: "Never manipulate a generator's electrical components if you are wet or standing in water."[4]
Don't use electrical equipment that has been under water until it has been thoroughly dried out and properly evaluated[4].
Before the next outage
- Transfer switch: to power house circuits, have a qualified electrician install one now[4], so a cord into a wall outlet is never the plan.
- CO alarms: test them[1], and replace detectors on the maker's schedule or every 5 years[3].
- Run spot: outside, at least 20 feet from the house[1], not on a porch or in a carport, with 3 to 4 feet[4] of clear space around and above.
- Fuel and cords: fuel in labeled, non-glass safety containers outside living areas, and outdoor-rated cords rated above what they will carry[2].
- The generator itself: "Regularly check and maintain your portable generator to ensure it will work properly when needed. Read and follow all labels, instructions and warnings on the generator and in the owner's manual."[1] Wisconsin's guidance is to start and load it at least once a month and keep fresh, conditioned fuel in it[6].
- Furnace vents: in a winter storm, "Clear snow away from the outside vents for fuel-burning appliances such as furnaces so that dangerous carbon monoxide does not build up in the house."[1]
If a generator ever poisons someone in your household, the CDC asks you to let the CPSC know[3]; the CPSC takes reports of product-related injuries at SaferProducts.gov[1].
Frequently asked questions
How far should a generator be from the house?
At least 20 feet[1], outside only, with the exhaust pointed away from the home, per the CPSC. The CDC says more than 20 feet[3] from any windows, doors and vents, and OSHA calls for 3 to 4 feet[4] of clear space on all sides and above the generator.
Can I run a generator in my garage with the door open?
No. The CPSC says opening doors or windows "will not provide enough ventilation to prevent the buildup of lethal levels of CO"[1], and the CDC says never to use a generator inside a home or garage, "even if doors and windows are open"[3].
Can I run a generator on a porch or in a carport?
No. The CPSC says a porch or carport is "too close to the home and puts your family at risk of CO poisoning"[1].
How long does carbon monoxide linger after a generator shuts off?
The CPSC says deadly levels can build up quickly in enclosed spaces "and can linger for hours, even after the generator has shut off"[2]. It gives no safe re-entry time, and OSHA says to stay out until trained, properly equipped personnel say the area is safe[4].
Can I plug my generator into a wall outlet?
No. That is backfeeding, which the CPSC calls "extremely dangerous," an electrocution risk to utility workers and neighbors served by the same transformer[2]. OSHA says to connect to house wiring only through a transfer switch installed by a qualified electrician[4].
Do I need a CO alarm if I use a generator?
Yes. The CDC says to use a battery-powered or battery backup CO detector in the home when using a generator[3], and the CPSC recommends alarms on each level and outside separate sleeping areas, tested monthly[1].
What are the symptoms of carbon monoxide poisoning?
The CDC lists headache, dizziness, weakness, upset stomach, vomiting, chest pain and confusion, often described as flu-like[3]. Generator CO can work fast enough that people pass out before they recognize symptoms[1], so get to fresh air at once and call 911[1].
Does a portable generator need a ground rod?
OSHA says to make sure a generator "is properly grounded and the grounding connections are tight" and to "Consult the manufacturer's instructions for proper grounding methods"[4]. Follow your manual, and for a connection to house wiring, ask the qualified electrician who installs the transfer switch.
Can I run a generator under a canopy in the rain?
The CPSC says to follow the manufacturer's wet-weather instructions, which may call for "an NFPA-rated non-combustible generator tent" or waiting "until rain or snow passes"[1]. Its safety alert describes "an open, canopy-like structure on a dry surface where water cannot reach it or puddle or drain under it"[2], and the 20-foot rule still applies[1].
Sources & References
- CPSC: As Winter Storms Threaten Millions in the U.S., CPSC Issues Safety Tips to Help Families Prevent Carbon Monoxide Poisoning and Fires (December 12, 2025, release 26-149; about 100 deaths a year from portable-generator CO; outside only, at least 20 feet from the house; not on a porch or in a carport; exhaust away from the home; CO shut-off feature; alarms on each level and outside sleeping areas, interconnected, tested monthly; manufacturer's wet-weather instructions; snow off furnace vents)
- CPSC: Portable Generator Hazards, Safety Alert, Publication 5123 (PDF) (primary hazards; most incidents indoors or in partially enclosed spaces; CO lingers for hours; at least 20 feet from doors, windows and vents; alarms certified to UL 2034, IAS 6-96 or CSA 6.19.01; danger labels since May 14, 2007; canopy on a dry surface; outdoor cords; backfeeding; fuel storage; refueling)
- CDC: Carbon Monoxide (CO) Poisoning Basics (symptoms; sleeping or drunk people can die before symptoms; more than 400 deaths, 100,000 emergency department visits and 14,000 hospitalizations a year; generators more than 20 feet from windows, doors and vents; replace detectors every 5 years)
- OSHA Fact Sheet FS-3286: Using Portable Generators Safely (PDF) (transfer switch installed by a qualified electrician; can energize wiring for great distances; grounded 3-prong cords; GFCIs; grounding per the manufacturer; canopy; 3 to 4 feet of clear space; fuel storage and refueling)
- CPSC: Stay Safe While Staying Warm This Winter (February 26, 2024) (92 CO deaths associated with generators in 2020, the most of any product category)
- Wisconsin DATCP: Generators (licensed electric contractor for permanent standby units; double-pole, double-throw transfer switch; tell the electric company; start and load at least once a month; fresh, conditioned fuel)
Related Articles
Home Generator Guide: Types, Sizing, Fuel and Safety
Guide • 14 min read
Carbon Monoxide Detector Placement: Where and How Many You Need
How-to • 11 min read
How Many Amps Does a Generator Produce? (Calculator + Chart)
Calculator • 9 min read
What Size Generator Do I Need? Appliance Wattage Calculator
Calculator • 11 min read
How Much Propane Does a Generator Use per Hour? (Charts + Tank Runtime)
Reference • 9 min read