Both kinds of portable air conditioner push the heat they remove outside through a hose in a window kit. They differ in where the air that carries that heat comes from, and the federal test that rates them spells out what that costs.
A single-hose portable typically pulls more outdoor air into the room than a comparable dual-hose unit, and DOE says that air "affects the capacity and efficiency"[3]. DOE's test already charges both types for it, so compare the SACC and CEER on the label. The federal minimum is the same for both: 7.83 CEER for a 10,000 SACC unit[4].
Where each type gets its condenser air
A portable cools room air across a cold coil and dumps the heat through a hot coil, the condenser, which needs its own stream of air. The federal definitions sort portables by where that stream comes from and where it goes[1].
- Single-duct (single-hose): it "draws all of the condenser inlet air from the conditioned space without the means of a duct, and discharges the condenser outlet air outside the conditioned space through a single duct"[1].
- Dual-duct (dual-hose): it "draws some or all of the condenser inlet air from outside the conditioned space through a duct", "may draw additional condenser inlet air from the conditioned space", and discharges through "a separate duct"[1].
- Combined-duct (hose-in-hose): "the condenser inlet and outlet air streams flow through separate ducts housed in a single duct structure", and DOE's test treats it like a dual-duct unit unless the procedure says otherwise[2].
So a hose-in-hose model can look like a single-hose unit while working like a dual-hose one. The product description or manual says which layout a model uses.
Why a single hose pulls outdoor air in
Every cubic foot of room air a single-hose unit blows outside has to be replaced, and the replacement leaks in from outdoors or from other rooms. EPA notes that single-hose units can bring smoke in "from elsewhere in the house"[5]. DOE's 2016 rule[3] puts the general point plainly: "single-duct portable ACs typically generate higher rates of infiltration air than comparable dual-duct units, and such infiltration affects the capacity and efficiency"[3].
A dual-hose unit draws its condenser air from outside and sends it back outside[1], so less room air leaves and less has to leak back in. DOE's definition still allows a dual-duct unit to take some condenser air from the room[1], which is why the test measures each unit rather than assuming zero.
How DOE rates both types
The test holds the room side at the same conditions for every portable. A dual-duct unit's condenser is fed outdoor-style air at two conditions; a single-duct unit draws room air, so its condenser sees room conditions[2].
| DOE test | Room air (dry bulb / wet bulb) | Condenser inlet air (dry bulb / wet bulb) | Units tested |
|---|---|---|---|
Hot condition | 80°F / 67°F | 95°F / 75°F | Dual-duct and combined-duct |
Milder condition | 80°F / 67°F | 83°F / 67.5°F | Dual-duct and combined-duct |
Single-duct condition | 80°F / 67°F | 80°F / 67°F (room air) | Single-duct |
DOE then works out an adjusted capacity for each outdoor condition, 95°F and 83°F[2]. Each one is the measured capacity minus the heat the ducts give back and minus the heat of the outdoor air that leaks in[2]. DOE computes that leaked-in air from the condenser air a unit blows out, and for a dual-duct unit it also uses the air drawn through the intake duct[2].
The leaked-in air is counted at the outdoor test temperature, with both its heat and its moisture[2]. In DOE's formula the dry-air part of that heat scales with the gap between outdoor air and the 80°F room: 15°F at the hot condition and 3°F at the milder one (95 − 80 = 15; 83 − 80 = 3). So on hot days each cubic foot that leaks in brings more heat.
The seasonal rating, SACC, weights the two results: 0.2 × the 95°F result plus 0.8 × the 83°F result[2]. In its 2016 rule DOE tied the hot condition to "high-temperature conditions when cooling is most needed" and the milder one to the "weighted-average temperature and humidity observed during the hottest 750 hours"[3]. The older industry test left these losses out, and DOE found the net cooling of portables "is generally significantly lower" than that test suggests, "primarily due to the effects of air infiltration"[3].
The hose adds heat too
The hot exhaust duct warms the room it passes through, and so does a dual-duct unit's intake duct carrying outdoor air. DOE measures each duct's surface temperature and counts its heat as surface area (circumference times length) times an "empirically-derived convection coefficient" of 3 Btu/h per square foot per °F[2], times how much warmer the duct is than the room. A longer hose has more surface, so keep the run as short as the window allows.
What the label tells you
SACC and CEER come out of that test, so they already include each layout's leaked-in air and duct heat[2]. Two units with the same SACC and CEER rate the same on DOE's test, whatever their hose count. The federal minimum for portables made from January 10, 2025[4] is one formula for single-duct and dual-duct units alike[4]:
| SACC (Btu/h) | Federal minimum CEER | Approximate draw at the minimum |
|---|---|---|
8,000 | 7.22 | 1,108 W |
10,000 | 7.83 | 1,277 W |
12,000 | 8.37 | 1,434 W |
14,000 | 8.85 | 1,582 W |
DOE's test assumes 750 cooling hours a year[2]. At the minimum, a 10,000 SACC unit would use about 958 kWh over those hours (1,277 × 750 ÷ 1,000), about $172 at 18 cents per kWh (958 × 0.18), near EIA's U.S. residential average of 18.19 cents for January to August 2026[7]. A unit with a higher CEER uses less in proportion: divide its SACC by its CEER to get its draw.
Do portable ACs pull in outside air?
A single-hose unit draws only room air through itself[1], but the air it blows outside is replaced by air leaking in from outdoors or from elsewhere in the house[5]. A dual-hose unit runs outdoor air through its own ducts and back outside[1], so it typically pulls less into the room[3].
Neither type delivers outdoor air to the room through the unit, so neither one ventilates it[1]. EPA notes that most home heating and cooling systems "do not mechanically bring fresh air into the house"[6]. For ventilation it points to opening windows and doors and to bathroom or kitchen fans that exhaust outdoors[6]; see how to improve indoor air quality.
Portable ACs and wildfire smoke
EPA's clean-room guidance names single-hose units directly: "Use portable air conditioners with a single hose sparingly in smoky conditions. Using these devices can bring more smoke inside from elsewhere in the house."[5] It gives no such warning for dual-hose units.
For the room itself, EPA says to close all its windows and doors and to "Use a portable air cleaner that is the right size for the room", run "continuously on the highest fan setting if you can", and pick one "that does not produce ozone"[5]. If an HVAC system or window air conditioner has a fresh air option, EPA says to turn it off, close the intake or set it to "recirculate" mode[5]. Where a commercial air cleaner isn't available or affordable, EPA describes a do-it-yourself box-fan filter as a temporary alternative[5].
Single-hose vs. dual-hose at a glance
| Single-hose | Dual-hose | |
|---|---|---|
Condenser air | From the room | From outside through an intake duct; some may come from the room |
Outdoor air pulled into the room | Typically more | Typically less |
Ducts giving heat to the room | Exhaust duct | Exhaust and intake ducts |
Federal minimum efficiency | 7.83 CEER at 10,000 SACC | 7.83 CEER at 10,000 SACC |
EPA wildfire smoke advice | Use sparingly | No specific advice |
Which should you choose?
Start from the label, not the hose count. These checks run in order.
- Size by SACC. Our BTU calculator estimates a room's load from ENERGY STAR's sizing chart.
- Among units with the same SACC, pick the higher CEER, since DOE's test has already charged each layout for its leaked-in air and duct heat[2].
- Lean toward a dual-hose or hose-in-hose unit for long runs in hot weather, because the heat of leaked-in air grows with the outdoor temperature in DOE's formula[2]. The same goes for smoke-prone areas, where EPA tells single-hose users to go sparingly[5].
- Keep the exhaust hose short and the filter clean: DOE says clean filters can lower an air conditioner's energy use by 5 to 15 percent[8].
For venting either type in a room without a standard window, see how to vent a portable AC without a window. For running costs at other rates and hours, see portable AC electricity cost.
Frequently asked questions
Are dual-hose portable ACs really better?
They typically pull less outdoor air into the room: DOE found single-duct units "typically generate higher rates of infiltration air than comparable dual-duct units", which affects capacity and efficiency[3]. On the label that difference is already in the SACC and CEER[2], so a single-hose unit with a higher CEER still rates as more efficient on DOE's test.
What is a hose-in-hose portable AC?
DOE calls it combined-duct: "the condenser inlet and outlet air streams flow through separate ducts housed in a single duct structure"[2]. It looks like one hose but carries its condenser air in from outside and back out, and DOE tests it like a dual-duct unit[2].
How much cooling does a single-hose unit lose?
It depends on the unit's condenser airflow and on how hot it is outside, so there's no single figure. DOE's test works it out for each model at 95°F and 83°F outdoor conditions[2] and reports the result as SACC, so the SACC on the box already reflects the loss.
Can I make a single-hose unit more efficient?
Keep the exhaust hose as short as the window allows, since DOE counts the duct's heat by its surface area[2]. Clean the filter, which DOE says can lower an air conditioner's energy use by 5 to 15 percent[8]. In smoky conditions, EPA advises using single-hose units sparingly[5].
Is a dual-hose unit worth the extra cost?
Work it out from the two labels. Yearly kWh is about SACC ÷ CEER × cooling hours ÷ 1,000, and DOE's test assumes 750 cooling hours a year[2]. Multiply each unit's kWh by your electricity rate and compare the yearly difference with the price difference.
Do portable ACs pull air from outside?
A single-hose unit does indirectly: the room air it blows out is replaced by air leaking in from outdoors or elsewhere in the house[5]. A dual-hose unit draws its condenser air from outside through a duct and returns it outside[1], so it typically pulls less into the room[3].
Does a portable AC bring in fresh air?
Not through the unit: a single-hose unit draws only room air, and a dual-hose unit keeps outdoor air in its own ducts[1]. For ventilation, EPA points to opening windows and doors and to bathroom or kitchen fans that exhaust outdoors[6].
Can I use a portable AC during wildfire smoke?
EPA says to "Use portable air conditioners with a single hose sparingly in smoky conditions"[5]. Close the room's windows and doors and run a portable air cleaner sized for the room on its highest setting, as EPA's clean-room guidance describes[5].
Sources & References
- 10 CFR 430.2 (Cornell LII): single-duct portable air conditioner (draws all of the condenser inlet air from the conditioned space, discharges it outside through a single duct) and dual-duct portable air conditioner (draws some or all of the condenser inlet air from outside through a duct, may draw additional condenser inlet air from the conditioned space, discharges through a separate duct)
- 10 CFR Part 430, Subpart B, Appendix CC (Cornell LII), portable air conditioner test procedure: combined-duct definition; Table 1 test conditions (room 80°F/67°F; condenser inlet 95°F/75°F and 83°F/67.5°F for dual-duct, 80°F/67°F for single-duct); duct heat from surface area (circumference × length) and a 3 Btu/h per sq ft per °F convection coefficient; infiltration air heat (sensible and latent) for single-duct and dual-duct units; SACC = 0.2 × ACC95 + 0.8 × ACC83; 750 cooling-mode hours a year
- DOE: Energy Conservation Program, Test Procedures for Portable Air Conditioners, final rule, 81 FR 35241 (June 1, 2016): single-duct units typically generate higher rates of infiltration air than comparable dual-duct units, affecting capacity and efficiency; net cooling generally significantly lower than the older industry test suggests; test conditions tied to the hottest 750 hours
- 10 CFR 430.32(cc) (Cornell LII): single-duct and dual-duct portable air conditioners made from January 10, 2025, CEER ≥ 1.04 × SACC ÷ (3.7117 × SACC^0.6384)
- EPA: Create a Clean Room to Protect Indoor Air Quality During a Wildfire (use single-hose portable ACs sparingly in smoky conditions; close the room's windows and doors; portable air cleaner sized for the room on the highest setting, no ozone; fresh air option off or recirculate; DIY box-fan cleaner as a temporary alternative)
- EPA: Improving Indoor Air Quality (most home heating and cooling systems don't mechanically bring fresh air into the house; windows and doors, bathroom and kitchen exhaust fans)
- EIA: Electric Power Monthly, Table 5.6.B (U.S. residential average 18.19 cents/kWh, January to August 2026)
- U.S. DOE: Energy Saver 101, Home Cooling (PDF): clean filters lower AC energy use 5 to 15 percent