What Size AC for 2,000 Sq Ft? (BTU & Tonnage Guide 2026)

A 2,000 sq ft home needs 2.5–4 tons (30,000–48,000 BTU) of air conditioning. Complete sizing guide with data tables for every climate zone, adjustment factors, and cost comparisons.

HVAC Base TeamUpdated February 5, 20269 min read

A 2,000 square foot home typically needs a 3-ton (36,000 BTU) air conditioner, with the range spanning from 2.5 tons in cool, well-insulated homes to 4 tons in hot climates with older construction. At 2,000 sq ft, you're in the most common home size range in America, and the difference between correct and incorrect sizing is 10–20% on your annual energy bill — $100–$300 per year.

This is the size where two-story homes start to benefit from zoning, and where the investment in higher-efficiency equipment (SEER2 18+) generates meaningful annual savings. Let's find your exact tonnage.

AC Size for 2,000 Sq Ft by Climate Zone

Climate ZoneCitiesBTU RangeTonnageEst. Annual Cool Cost
Zone 1 (Hot-Humid)Miami, Key West50,000–60,0004–5 ton$800–$1,100
Zone 2 (Hot)Houston, Phoenix, Tampa44,000–56,0003.5–4.5 ton$650–$950
Zone 3 (Warm)Atlanta, Dallas, Charlotte40,000–50,0003–4 ton$500–$750
Zone 4 (Mixed)Nashville, DC, St. Louis36,000–44,0003–3.5 ton$400–$600
Zone 5 (Cool)Chicago, Denver, Boston32,000–40,0002.5–3 ton$300–$450
Zone 6 (Cold)Minneapolis, Milwaukee28,000–36,0002.5–3 ton$200–$350

Single-Story vs. Two-Story: Sizing Differences

At 2,000 sq ft, your home layout significantly impacts sizing:

LayoutSizing ConsiderationTypical Tonnage (Zone 4)
Single-story ranch (2,000 sq ft one floor)Large roof exposure, simple ductwork3–3.5 ton
Two-story (1,000 per floor)Less roof exposure, but upper floor runs hotter3 ton (1 system with zoning) or 1.5 + 2 ton (2 systems)
Split-levelComplex duct routing, natural temperature zones3 ton with zoning dampers
L-shaped or U-shapedLong duct runs to distant rooms3–3.5 ton (consider duct layout)
Pro Tip

Two-story 2,000 sq ft homes benefit most from zoning. A single 3-ton system with a zoning damper system ($500–$1,500 addon) directs more airflow upstairs during the day and balances at night. Without zoning, the downstairs stays at 72°F while the upstairs struggles at 78°F.

Sizing Examples

Real-World Example

Example 1: 2,000 sq ft two-story colonial in Richmond, VA (Zone 4)

1,000 sq ft per floor. Average insulation (2001 build). 9-ft first floor, 8-ft second floor. Standard windows. Ducts in attic for second floor, in basement for first.

  • Base: 2,000 × 20 = 40,000 BTU
  • Mixed ceiling heights: +6% average = 42,400
  • First-floor ducts (conditioned space): −5% for half = 41,280
  • Second-floor attic ducts: +10% for half = 43,344

Result: 43,344 BTU → 3.5-ton system. A 3.5-ton two-stage or variable-speed unit is ideal — it runs on low stage (2.1–2.5 tons) during mild weather and ramps to 3.5 tons on the hottest days. Add zoning for optimal floor-by-floor comfort.

Real-World Example

Example 2: 2,000 sq ft new-build ranch in San Antonio, TX (Zone 2)

Single-story, 9-ft ceilings, excellent insulation (2026 code), Low-E windows, sealed ducts in conditioned attic, open-plan kitchen/living.

  • Base: 2,000 × 22 = 44,000 BTU
  • Excellent insulation: −20% = 35,200
  • 9-ft ceilings: +12% = 39,424
  • Conditioned-space ducts: −10% = 35,482
  • Kitchen: +4,000 = 39,482
  • Humidity: +10% = 43,430

Result: 43,430 BTU → 3.5-ton system. Even with excellent insulation, San Antonio's heat and humidity push a new 2,000 sq ft home to 3.5 tons. The good news: a SEER2 20 system at 3.5 tons costs only $45–$60/month to operate versus $70–$95 at SEER2 14.

Real-World Example

Example 3: 2,000 sq ft Cape Cod in Boston, MA (Zone 5)

1.5-story (1,200 sq ft main + 800 sq ft finished attic). Insulation upgraded (R-21 walls, R-49 attic). 8-ft ceilings main, 7-ft kneewalls in attic.

  • Base: 2,000 × 18 = 36,000 BTU
  • Good insulation: −10% = 32,400
  • Attic rooms (heat gain): +15% for 800 sq ft portion = 36,180
  • Average ductwork: +0% = 36,180

Result: 36,180 BTU → 3-ton system. The finished attic rooms add load that almost exactly offsets the insulation savings. A 3-ton system is the sweet spot. Consider a mini split head in the attic space for supplemental cooling if it runs hot.

Equipment Options and Costs (2026)

System TypeTonnageInstalled CostSEER2Annual Cool Cost (Zone 3)
Single-stage central AC3 ton$4,000–$6,00014–15$550–$650
Two-stage central AC3 ton$5,500–$8,00017–19$400–$500
Variable-speed central AC3 ton$7,000–$11,00020–24$300–$400
Standard heat pump3 ton$5,500–$8,50016–19$350–$500 (heat+cool)
Cold-climate heat pump3.5 ton$7,500–$12,00017–22$400–$550 (heat+cool)
Ductless mini splits (4-zone)36K total$8,000–$14,00018–28$280–$400

When 2,000 Sq Ft Needs Two Systems

A single system works for most 2,000 sq ft homes, but these scenarios warrant two units:

  • Two-story home with no basement (attic-only ductwork): Two 1.5-ton systems (one per floor) often outperform one 3-ton system with long duct runs
  • Home with an addition: Original 1,500 sq ft + 500 sq ft addition — the addition often can't connect to existing ductwork efficiently
  • Extreme climate (Zone 1–2) with poor insulation: Total load exceeds 5 tons
  • Ranch with a finished detached room: Mother-in-law suite, workshop, or ADU needs independent system
Key Takeaway

Key Takeaways

  1. Most 2,000 sq ft homes need 3 tons (36,000 BTU) — the most common residential AC tonnage
  2. Range: 2.5 tons (cool climate, great insulation) to 4+ tons (hot climate, poor insulation)
  3. Two-story homes benefit significantly from zoning ($500–$1,500 addon) for floor-by-floor comfort
  4. New construction (2020s code) needs 0.5–1 ton less than older homes of the same size
  5. The jump from SEER2 14 to SEER2 20 saves $150–$250/year at this home size — payback in 5–8 years
  6. At 2,000 sq ft, a single well-designed system beats two smaller systems in almost every scenario